eISSN: 2299-0054
ISSN: 1895-4588
Videosurgery and Other Miniinvasive Techniques
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2021
vol. 16
 
Share:
Share:
abstract:
Original paper

Computed tomography-guided core needle biopsy for lung nodules: low-dose versus standard-dose protocols

Yi-Yang Huang
1
,
Hong Cheng
1
,
Guang-Chao Li
2

1.
Medical College, Yangzhou University, Yangzhou, China
2.
Department of Radiology, No. 6 Hospital of Shanghai Jiaotong University, Shanghai, China
Videosurgery Miniinv 2021; 16 (2): 355–361
Online publish date: 2021/02/03
View full text Get citation
 
PlumX metrics:
Introduction
Computed tomography (CT)-guided core needle biopsy (CNB) is an essential step in the management of lung nodules (LNs). Low-dose CT (LDCT)-guided CNB has been used to decrease the radiation exposure.

Aim
To evaluate the technical success, safety, diagnostic capacity, and radiation exposure to patients between LDCT-guided and standard-dose CT (SDCT)-guided CNB for LNs.

Material and methods
This is a retrospective, single-centre study. Patients who underwent LDCT-guided or SDCT-guided CNB for LNs from January 2015 to December 2017 were included. Data on technical success, diagnostic performance, complications, and radiation exposure were collected and analysed.

Results
A total of 70 and 65 patients underwent LDCT-guided and SDCT-guided CNB procedure, respectively. The technical success rates were 100% in both groups. The diagnostic yield, sensitivity, specificity, and overall diagnostic accuracy in the LDCT and SDCT groups were 71.4% and 67.7% (p = 0.637), 97.8% and 93.2% (p = 0.625), 100%, and 100%, and 98.6% and 95.4% (p = 0.560), respectively. The independent risk factor of diagnostic failure was less sample tissues (p = 0.012; 95% confidence interval: 0.033–0.651). Pneumothorax was found in 9 and 12 patients in the LDCT and SDCT groups, respectively (p = 0.369). Lung haemorrhage was found in 11 and 12 patients in the LDCT and SDCT groups, respectively (p = 0.671). The mean dose-length product was 38.3 ±17.0 mGy · cm and 376.0 ±118.7 mGy · cm in the LDCT and SDCT groups, respectively (p < 0.001).

Conclusions
Compared to SDCT, LDCT-guided CNB can provide comparable safety and diagnostic performance for LNs while reducing exposure to radiation.

keywords:

low-dose, computed tomography, lung nodule, biopsy

  
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.