Diagnostic investigation of breast magnetic resonance imaging in malignant and benign mass lesions

Masoumeh Gity, Ali Arabkheradmand, Elham Taheri, Madjid Shakiba

Arch Med Sci 2018; 14, 5: 1061–1069
Online publish date: 2016/09/12
Article file
Get citation
ENW
EndNote
BIB
JabRef, Mendeley
RIS
Papers, Reference Manager, RefWorks, Zotero
AMA
APA
Chicago
Harvard
MLA
Vancouver
 
 

Introduction

Breast magnetic resonance imaging (BMRI) has been identified as a valuable modality in the diagnosis of breast cancer [1, 2], and monitoring the response to chemotherapy [3–5]. The sensitivity of breast MRI for diagnosing invasive breast cancer has been reported between 88% and 100%, surpassing all other conventional modalities such as mammography and ultrasound [6]. However, its specificity in discriminating malignant from benign lesions is highly varied, reported in the range of 35% to 90% [7, 8]. Different lesions found in breast MRI include enhancing masses, non-mass-like enhancing lesions and enhancing foci.
The MRI BI-RADS lexicon has been developed in order to obtain a standard system of reporting. This lexicon defines morphologic and kinetic descriptors for assessing breast lesions and finally scores the lesion in a range of BI-RADS categories from 0 to 6. Although some paradigms for interpretation and scoring of the lesions in the BI-RADS system have been proposed, the final scoring is somewhat subjective. As the assessment is based on different morphologic and dynamic criteria, a critical question is the relative importance of each descriptor in the final assessment of breast MRI which could optimize the accuracy of the MRI report. A review of the literature shows that there have been similar studies with different approaches in this issue [9–12].
In this study, our goal was to evaluate the importance of each BI-RADS descriptor of “enhancing masses” and its relation to benign outcome or malignant pathology among a group of patients with a final assessment of BI-RADS categories 3-5.

Material and methods

Patient enrolment

The study was approved by the ethics committee of the Tehran University of Medical Sciences. In a database of patients referred from September 2007 until March 2013, for breast MRI, we included patients with a final assessment BI-RADS categories 3, 4 and 5 who had a pathological examination of MRI-detected breast lesions. Tissue sampling included core needle/vacuum-assisted image guided biopsy before the operation, post-operative pathologic examination, or both. We excluded patients with a previous biopsy-proven malignancy (BI-RADS category 6), any history of neo-adjuvant chemotherapy or those who showed a discrepancy between the pre-operative and post-operative pathology results. We included the follow-up of patients who did not have surgery, and those without follow-up MRI for at least 12 months were excluded. In addition, as we did not have access to MRI-guided biopsy in that period, we excluded patients who were referred to other centers for MRI-guided biopsy.
Finally, 433 enhancing mass lesions (in 312 patients) were enrolled in the study. Among these masses, 117 had a BI-RADS category of 3 (probably a benign finding), 263 had a BI-RADS category of 4 (suspicious lesions) and 53 had a BI-RADS category of 5 (highly suggestive of malignancy) (Figures 1 and 2). In addition to evaluation of the recent mammography, second look ultrasound examination was obtained for all BI-RADS 4 and 5 category enhancing masses on MRI.
In case of positive ultrasound or mammographic findings that could be correlated with the MRI enhancing mass, core needle biopsy with a 14-gauge needle or vacuum-assisted biopsy with a 9- or 12-gauge needle was performed.
A small group of enhancing masses with BI-RADS 3 category assessment that could not be localized on ultrasound examination or mammography was followed by a 6- and 12-month MRI. Also some patients with BI-RADS 4 category masses who did not undergo MRI-guided biopsy and had follow-up MRI in our institute were included.
All 53 patients with BI-RADS 5 category masses underwent image-guided biopsy, finally confirmed by surgery. The masses with a stable or downgraded BI-RADS score after 12 months were considered as benign and were scheduled for follow-up by sonography and/or screening mammography depending on the patient’s age.

Magnetic resonance imaging protocol

Magnetic resonance imaging was conducted using a 1.5T Signa system (General Electric Medical Systems, USA) with a bilateral phased-array 4-channel breast coil. All patients were scanned in the prone position. Among the premenopausal patients, MRI was conducted during the second week of their menstrual cycle, whenever possible. Axial T1-weighted and axial STIR images were obtained, followed by six series of axial dynamic T1-weighted three-dimensional, fat-suppressed spoiled gradient-echo, one set prior to and five series after the rapid bolus injection of 0.1 mmol/kg gadolinium-DTPA (Dotarem, Guerbet), followed by a 15 ml saline injection.
The axial T1-weighted sequence was obtained with the following parameters: TR/TE: 400/10; BW: 31.25 Hz/pixel; FOV: usually 32 mm; slice thickness: 5.0 mm; matrix size: 384 × 256; NEX: 1. The parameters of axial STIR were as follows: TR/TE: 4500/63; bandwidth: 62.50; FOV: usually 32; slice thickness: 5.0 mm; matrix size: 320 × 256; NEX: 1. A dynamic T1-weighted three-dimensional, fat-suppressed spoiled gradient-echo sequence with the following parameters was obtained: TR/TE: 9/4; BW: 31.25; FOV: 32; slice thickness: 4.0 mm with no intersection gap; matrix size: 352 × 288; NEX: 1; FA: 300.
The dynamic series were obtained every 60–90 s, so all six series were performed within 9 min of IV contrast injection. MR mammograms were interpreted by a dedicated, sub-specialized, expert radiologist with more than 15 years of experience in breast imaging. The assessment of morphologic configuration and kinetic enhancement was based on the American College of Radiology BI-RADS MRI lexicon version 4. We used CAD-STREAM for a systematized interpretation of MR mammograms and five series of three-dimensional subtracted images were processed by CAD-stream Confirma. The morphologic configurations included focus/foci (punctuate dots of enhancement smaller than 5 mm), mass (enhancing masses that had space-occupying features larger than 5 mm) and non-mass-like enhancement (areas of enhancement that had neither tri-dimensional shape nor typical mass characteristics) [13]. Lesions showing slow initial contrast enhancement (less than 50% enhancement in the first 60–90 s) were excluded, and those with 50–100% and more than 100% initial rise of the time-intensity curve were named as intermediate (non-rapid) and rapid type of curves respectively. Among three types of time-intensity curves including persistent, plateau and rapid-wash out, the most concerning curve type in each lesion was considered for interpretation. Based on morphologic and kinetic enhancement characteristic results, all patients were assigned a BI-RADS-category score of 0–6 [14].

Statistical analysis

We reviewed enhancing masses on breast MRI with BI-RADS 3, 4, and 5 assessment categories, and compared different MRI findings descriptors with final outcome of the patients. We used the chi square test for assessment of statistical difference of categorical variables among malignant and benign lesions. In order to calculate diagnostic indices including sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio, we used the cross tabulations in dichotomized variables, and we also calculated the odds ratios based on these tables. In addition, multivariate logistic regression analysis was used for assessment of malignancy as the dependent variable and different descriptors to find the independent MRI descriptors which could predict the malignancy.
All data were analyzed using SPSS ver. 16 for Windows (SPSS Inc., Chicago, IL, USA). A p-value < 0.05 was accepted to be statistically significant.

Results

In a retrospective study we searched a database of pathologically proven breast lesion patients who underwent dynamic contrast-enhanced breast MRI examination before operation or biopsy, and finally 433 masses among 312 patients were evaluated. The mean age of the patients was 45.1 ±10.5 years (range: 18 to 83 years). Among breast lesions, 198 (45.7%) were positioned in the right breast and 235 (54.3%) were detected in the left breast. The most common location was upper outer quadrant (UOQ) (21.7%) followed by lower outer quadrant (LOQ) (20.8%). In total, 88 (20.3%) observed masses were malignant. The most frequent BI-RADS score was 4 (n = 263, 60.7%), followed by 3 (n = 117, 27%). Distribution of other imaging characteristics of the mass lesions is summarized in Table I. Keeping in mind the fact that early background enhancement may obscure some details, the reported early background enhancement was observed in 89 (26.7%) of 312 patients. The most common shape of the masses was an oval/lobulated shape that was seen in 288 lesions (66.5%) (Table I).
The mean diameter of the enhancing masses was 12.4 ±6.1 mm (range: 5–40), and 117 (33.6%) lesions had a diameter less than 10 mm. The mean diameter of benign and malignant masses was 11.6 ±5.4 mm and 15.7 ±7.5 mm, respectively (p < 0.0001). The association of different BI-RADS descriptors with malignancy was assessed. In our study group selected based on mentioned inclusion and exclusion criteria, masses greater than 10 mm were more associated with malignancy (26.4% vs. 7.7%, p-value < 0.001).
The frequency of malignant and benign pathologies in each descriptor is presented in Table II. In all descriptors except for enhancement type, the distribution of malignancy was statistically different in subgroups.
In the cross tabulation, in each descriptor group, the subclass that showed the highest association with malignancy was determined. For example, among all subclasses of shape (including round, oval/lobulated and irregular shapes), the frequency of malignancy was higher in irregular masses (38% in irregular, 16.7% in oval/lobulated and 15.2% in round masses). Based on the highest association with malignancy, we categorized each descriptor into two groups, the first group with the highest frequency of malignancy and the second group consisting of other descriptors. For example, regarding shape, the irregular subclass was considered as the first group and the two other subclasses (including oval/lobulated and round masses) were integrated in one group as the second group. We cross-tabulated these two new groups of BI-RADS descriptors with the pathology results and calculated the odds ratio and diagnostic indices including sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio (Tables III and IV).
In a multivariate logistic regression analysis in which the pathology result was considered as the dependent variable and the above-mentioned dichotomized BI-RADS descriptors were considered as the independent variables, the Cox model R square was 0.23 and the size, margin, enhancement type and curve type remained significant in the model, while the shape and internal enhancement did not have a significant p-value in the model (Table V).

Discussion

Magnetic resonance imaging can detect breast cancers that are occult in other imaging modalities or physical examination. The sensitivity of MRI for breast cancer is higher than 90% (94–99%), while regarding overlapping features among malignant and benign lesions; its specificity is significantly lower and remains variable, leading to considerable false positive results and unnecessary invasive diagnostic procedures [2, 3, 14–16].
Most malignant breast tumors are highly vascular and are easily discovered in contrast-enhanced MRI. In addition, there are many benign lesions that are hypervascular and may cause difficulty in interpretation of the breast MRI. Some benign lesions such as fibrocystic changes and sclerosing adenosis have been presented as misleading pathologies in recent articles [17–19]. In this study, we observed similar overlapping with a wide range of benign lesions in our false positive results, especially in the BI-RADS 4 category. Accordingly, any improvement in the imaging methods and interpretation leading to higher specificity of breast MRI without sacrificing the sensitivity would be a considerable achievement. Since in the MRI BI-RADS reporting system, the radiologist is dealing with multiple morphologic and kinetic descriptors, defining the relative importance of each descriptor seems to be useful for this purpose.
In this article, we assessed the odds ratio (OR) and also diagnostic indices of each MRI descriptor in enhancing breast masses. Based on our proposed grouping for descriptors, the highest odds ratio was seen for margin, followed by the dynamic curve type, mass size, and shape.
On the other hand, we assessed diagnostic indices of each descriptor individually in malignant breast masses that showed high sensitivity and low specificity in the type of enhancement, curve type, and size, while this analysis showed high specificity (fewer unnecessary procedures) and a low sensitivity for shape and margin. In addition, for internal enhancement, both sensitivity and specificity were in a medium range. These findings mean lower false positive results could be achieved by considering morphologic indices, while lower false negative results are obtained in dynamic curves and lesion size.
Some other studies have focused on the rate of false positive and false negative results of the MRI BI-RADS final assessment. They have also assessed the relative importance of each descriptor in MRI BI-RADS. Mahoney et al. reported 29% of their BI-RADS 5 and 79% of their BI-RADS 4 lesions as benign pathologies positive predictive value (PPV) equal to 71% and 21%, respectively) [9]. In another study, 33% and 81% of BI-RADS 5 and 4 lesions were benign (PPV equal to 67% and 19%, respectively) [20]. In our series, 18.9% of BI-RADS 5 and 84.4% of BI-RADS 4 lesions were benign (PPV equal to 81.1% and 15.6%, respectively).
As observed in different studies, the rate of false positive cases is considerable, especially in BI-RADS 4 lesions. This means that the current policy of breast lesion management has been adjusted based on a conservative set point to decrease the cancer-missing rate at the cost of performing unnecessary invasive procedures.
In the review of the literature, we found some studies focusing on the efficacy of each descriptor of breast MRI [9–12, 21–26]. In spite of somewhat different designs and settings, the general goal of these studies is to assess the relative importance of each descriptor in the diagnosis of malignant breast lesions.
In an overall view, our results showed a good sensitivity (and thus a low cancer-missing rate) for size, enhancement type and curve type of kinetic assessment, while it showed a good specificity (and thus a decreased false positive rate leading to fewer unnecessary invasive procedures) among patients for morphologic descriptors of shape and margin. In addition, the best OR was seen for margin and curve type, then for size and shape, and other descriptors showed lower ORs. Findings of other studies were quite similar to our study; however, there were different results among other studies. These differences were related to stronger or weaker diagnostic indices in different descriptors; as mentioned, these differences are partly related to inhomogeneous settings and patient enrollment settings among these studies. Gutierrez et al. reported ORs of 2.8–4.6 for size, shape, margin and internal enhancement in diagnosis of malignancy [20]. However, they considered only BI-RADS 4 and 5 lesions. This could lower the indices, as the most lesions that lower diagnostic indices are BI-RADS 4 lesions, and excluding BI-RADS 3 lesions could decrease the diagnostic indices and ORs. The positive likelihood ratio of morphologic characteristics (including irregular shape, spiculated margin and heterogeneous internal enhancement) in the study of Baltzer et al. was similar to our study [10]. Mahoney et al. reported that among 121 enhancing masses, irregular shape, spiculated and irregular margins and rapid internal enhancement were most predictive of malignancy [9]. In the study of Wedegärtner et al., irregular lesion contour (margin) had the best efficacy in determining malignancy (sensitivity and specificity of 83% and 76%, respectively) [12]. Thus, compared to our findings, in somewhat lower specificity, they obtained a significantly better sensitivity for margin. Considerable power of spiculated margin presence for malignancy was reported by Schnall et al. [11] In addition, they stated that kinetic characteristics are among the most reliable criteria suggestive for malignancy. Tozaki et al. reported a spiculated margin to be suggestive of malignancy in all masses and an irregular shape to be related to malignancy in 97% of cases [21].
To find independent MRI descriptors that could predict malignancy, we performed a multivariate analysis, in which margin, size and kinetic characteristics were statistically significant variables. Similarly, Gutierrez et al. found shape as a less significant descriptor of BI-RADS in the multivariate model [20]. Although more powerful variables such as “margin” do not exclude the less powerful descriptors such as “shape” from the multivariate model in the current study, based on our results, neither morphology nor kinetic characteristics have been completely excluded from the model in our study. We can conclude that both morphologic and kinetic descriptors bear a valid weight in the diagnosis of masses and neither could be ignored.
Finally, the new BI-RADS lexicon seems to be more efficient in discrimination of malignant and benign lesions and may increase sensitivity while not sacrificing specificity, and as a result reduces unnecessary biopsy and patient anxiety. Future studies should compare the results.
In conclusion, it seems that morphologic descriptors of MRI BI-RADS are highly specific while kinetic related descriptors are highly sensitive in diagnosis of malignant masses of the breast. Appropriate consideration and combination of different BI-RADS findings could help in better interpretation of MRI BI-RADS and lowering the rate of false reports.

Conflict of interest

The authors declare no conflict of interest.

References

1. Mann RM, Kuhl CK, Kinkel K. Breast MRI: guidelines from the European Society of Breast Imaging. Eur Radiol 2008; 18: 1307-18.
2. Sardanelli F, Giuseppetti GM, Canavese G, Cataliotti L, Corcione S. Indications for breast magnetic resonance imaging. Consensus document “Attualità in senologia”, Florence 2007. Radiol Med 2008; 113: 1085-95.
3. Martincich L, Montemurro F, Cirillo S, Marra V, De Rosa G. Role of magnetic resonance imaging in the prediction of tumor response in patients with locally advanced breast cancer receiving neoadjuvant chemo-therapy. Radiol Med 2003; 106: 51-8.
4. Londero V, Bazzocchi M, Del Frate C, et al. Locally advanced breast cancer: comparison of mammography, sonography and MR imaging in evaluation of residual disease in women receiving neoadjuvant chemotherapy. Eur Radiol 2004; 14: 1371-9.
5. Thukral A, Thomasson DM, Chow CK, et al. Inflammatory breast cancer: dynamic contrast-enhanced MR in patients receiving bevacizumab – initial experience. Radiology 2007; 244: 727-35.
6. Zakhireh J, Gomez R, Esserman L. Converting evidence to practice: a guide for the clinical application of MRI for the screening and management of breast cancer. Eur J Cancer 2008; 44: 2742-52.
7. Rankin SC. MRI of the breast. Br J Radiol 2000; 73: 806-18.
8. Uematsu T, Kasami M. MR imaging findings of benign and malignant circumscribed breast masses: part 2. Cystic circumscribed masses. Jpn J Radiol 2009; 27: 405-9.
9. Mahoney MC, Gatsonis C, Hanna L, DeMartini WB, Lehman C. Positive predictive value of BI-RADS MR imaging. Radiology 2012; 264: 51-8.
10. Baltzer PA, Benndorf M, Dietzel M, Gajda M, Runnebaum IB. False-positive findings at contrast-enhanced breast MRI: a BI-RADS descriptor study. AJR Am J Roentgenol 2010; 194: 1658-63.
11. Schnall MD, Blume J, Bluemke DA, DeAngelis GA, DeBruhl N. Diagnostic architectural and dynamic features at breast MR imaging: multicenter study. Radiology 2006; 238: 42-53
12. Wedegärtner U, Bick U, Wörtler K, Rummeny E, Bongartz G. Differentiation between benign and malignant findings on MR-mammography: usefulness of morphologicalcriteria. Eur Radiol 2001; 11: 1645-50.
13. Heywang-Köbrunner SH, Viehweg P, Heinig A, Küchler C. Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions. Eur J Radiol 1997; 24: 94-108.
14. Mann RM, Kuhl CK, Kinkel K, Boetes C. Breast MRI: guidelines from the European Society of Breast Imaging. Eur Radiol 2008; 18: 1307-18.
15. Schnall MD, Ikeda DM. Lesion Diagnosis Working Group report. J Magn Reson Imaging 1999; 10: 982-90.
16. American College of Radiology. Breast Imaging Reporting and Data System Atlas (BI-RADS Atlas). Reston, VA: American College of Radiology 2003.
17. Chen JH, Nalcioglu O, Su MY. Fibrocystic change of the breast presenting as a focal lesion mimicking breast cancer in MR imaging. J Magn Reson Imaging 2008; 28: 1499-505.
18. Oztekin PS, Tuncbilek I, Kosar P, Gültekin S, Oztürk F. Nodular sclerosing adenosis mimicking malignancy in the breast: magnetic resonance imaging findings. Breast J 2011; 17: 95-7.
19. Liberman L, Morris EA, Lee MJ, et al. Breast lesions detected on MR imaging: features and positive predictive value. AJR Am J Roentgenol 2002; 179: 171-8.
20. Gutierrez RL, DeMartini WB, Eby PR, et al. BI-ADS lesion characteristics predict likelihood of malignancy in breast MRI for masses but not for non mass like enhancement. AJR Am J Roentgenol 2009; 193: 994-1000.
21. Tozaki M, Igarashi T, Fukuda K. Positive and negative predictive values of BI-RADS-MRI descriptors for focal breast masses. Magn Reson Med Sci 2006; 5: 7-15.
22. Cho YH, Cho KR, Park EK, Kyoung Seo B, Woo OH. Significance of additional non-mass enhancement in patients with breast cancer on preoperative 3T dynamic contrast enhanced MRI of the breast. Iran J Radiol 2016; 13: e30909.
23. Gity M, Ghazi Moghadam K, Jalali AH, Shakiba M. Association of different MRI BIRADS descriptors with malignancy in non-mass-like breast lesions. Iran Red Crescent Med J 2014; 16: e26040.
24. Chen M, Zhan WW, Wang WP. Cystic breast lesions by conventional ultrasonography: sonographic subtype-pathologic correlation and BI-RADS Assessment. Arch Med Sci 2014; 10: 76-83.
25. Sadr SSH, Javanbakht J, Norouzi Javidan A, Ghaffarpour M, Khamse S. Descriptive epidemiology: prevalence, incidence, sociodemographic factors, socioeconomic domains, and quality of life of epilepsy: an update and systematic review. Arch Med Sci DOI: 10.5114/aoms.2016.60377.
26. Rzymski P, Wysocki PJ, Kycler W, Opala T. Correlation between insulin resistance and breast elasticity heterogeneity measured by shear wave elastography in premenopausal women – a pilot study. Arch Med Sci 2011; 7: 1017-22.
Copyright: © 2016 Termedia & Banach. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
FEATURED PRODUCTS
Quick links
© 2018 Termedia Sp. z o.o. All rights reserved.
Developed by Bentus.
PayU - płatności internetowe