ISSN: 1899-1955
Human Movement
Current issue Articles in Press Archive Special Issues About the journal Editorial board Instructions for Reviewers Journal's Reviewers Ethical standards and procedures Abstracting and indexing Contact Instructions for authors
SCImago Journal & Country Rank
 
2/2017
vol. 18
 
Share:
Share:
more
 
 
abstract:
Original paper

Intra- and inter-examiner reliability in angular measurements of the knee with a smartphone application

Viviane Derhon
1
,
Rafael Aparecido Santos
1
,
Michelle Brandalize
2
,
Danielle Brandalize
1
,
Luciano Pavan Rossi
1

1.
Central West State University, Guarapuava, Brazil
2.
Faculty Campo Real, Guarapuava, Brazil
Online publish date: 2018/02/26
View full text
Get citation
ENW
EndNote
BIB
JabRef, Mendeley
RIS
Papers, Reference Manager, RefWorks, Zotero
AMA
APA
Chicago
Harvard
MLA
Vancouver
 
Purpose
Goniometric smartphone applications to measure joint angles offer greater practicality and accessibility, which makes them potential alternatives to a conventional goniometer. The aim of the present study was to evaluate the intra- and inter-examiner reliability in measuring the angles of the range of motion of the knee with the use of the ROM© goniometric smartphone application.

Method
The total of 34 young healthy women with an at least 20° limitation in knee extension range of motion participated in the study. Angular measurements of knee flexion in the dominant leg were performed with the aid of the smartphone application by three trained examiners for the evaluation of the inter-examiner reliability. The second evaluation was carried out after a 48-hour period for the determination of the intra-examiner reliability.

Results
The proposed method demonstrated excellent intra-examiner (intra-class correlation coefficient [ICC] > 0.80) and inter-examiner (ICC > 0.90) reliability, with good intra-examiner (r > 0.85) and strong inter-examiner (r > 0.90) correlations (p < 0.0001), an intra-examiner coefficient of determination (R2) of 0.75, inter-examiner R2 of 0.91, and good level of agreement on the Bland-Altman plots for the measures.

Conclusions
The findings reveal that the ROM© goniometric smartphone application can be considered a useful tool for the evaluation of the knee range of motion in healthy women.

keywords:

smartphone, joint range of motion, knee, reproducibility of measurements