Introduction

Cardiac resynchronisation therapy defibrillation (CRT-D) is recommended as a class I indication in symptomatic patients treated with optimal medical therapy with sinus rhythm, ejection fraction (EF) ≤ 35%, and complete left bundle branch block conditions. This therapy has positive effects on mortality and morbidity in patients with heart failure with reduced ejection fraction (HFrEF) [1].

Atrial fibrillation (AF) is a cardiac arrhythmia characterised by no recognisable P wave and irregular R-R interval on electrocardiogram (ECG). Its frequency is 3% over 20 years [2]. There must be at least 30 s of attack for AF diagnosis [3]. This attack can be symptomatic or asymptomatic (silent) in patients [4]. Silent AF may be very frequent in elderly and HF patient groups.

CRT-D devices are used in the treatment of HF patient groups. They also can record the cardiac arrhythmias. Atrial fibrillation attacks are frequent in CRT-D–implanted HF patients because of risk factors such as left atrial dilatation (LAE), P-wave dispersion (Pdisp), increased left atrial volume index (ILAV), and especially left ventricle (LV) dilatation.

Atrial fibrillation attacks can be silent, symptomatic, or emerge with its complications in pacemaker-implanted patient groups [5]. The cumulative yearly incidence of AF can be 30–40% in these patients. Silent AF attacks are as frequent as symptomatic ones in this group, but there are limited data about its predisposing risk factors in the literature [6, 7].

Increased P-wave duration and prolonged PR interval in leads DII, DIII, and aVF of a surface ECG are defined as diagnostic criteria of left atrial anomaly [810]. P-wave duration index (PWDI) has been described for the first time, which is calculated by dividing the P-wave duration (PWD) by the PR interval [11]. It was reported that recurrence is higher in AF ablated patients with increased PWDI. This parameter is obtained by dividing the P-wave duration, which is the indicator of the atrial conduction, by the PR interval, which is the time taken by the electrical signals to travel from the atrium to the atrioventricular node, and it reflects the conduction heterogeneity, which was thought to be a parameter for predicting silent AF detection.

This study aimed to investigate the relation between PWDI and silent AF development in CRT-D-applied patients.

Material and methods

Patient population

Permission for this study was obtained from the Local Ethics Committee. Between 2010 and 2016, 301 patients underwent CRT-D implantation in our clinic. Of these, 62 patients had symptomatic AF attacks. Death was observed in 10 patients for any reason. We excluded 15 patients with atrial pacing because the PR interval can be changed by the device. Nineteen patients with chronic diseases were also excluded (such as chronic kidney disease, cerebrovascular diseases, chronic obstructive lung disease). These patients were excluded from the study because they could not be clearly differentiated due to AF attack or chronic diseases. Our inclusion criteria were complete left bundle branch block presence on ECG, EF < 35%, and taking optimal medical therapy but still New York Heart Association (NYHA) Class 3–4 functional capacity. As a result, we included 181 patients in our retrospective study.

Laboratory assessment

Kidney functions, lipid levels, high-sensitivity C-reactive protein (hs-CRP), uric acid, N-terminal pro-natriuretic peptide (NT-proBNP), thyroid functions, and complete blood count were recorded from blood taken at the time of admission.

Electrocardiographic and echocardiographic assessment

Twelve-lead surface ECGs of all patients were recorded by a MAC 2000 ECG Machine (GE Medical Systems Information Technologies, Inc., WI, USA) before the CRT-D implantation. Electrocardiograms had 25 mm/s speed and 1 mv/10 mm standard calibration. The onset and end of the P wave were defined as the point of the first visible upward slope from the isoelectric line and the point of return to the isoelectric line, respectively. The PR interval was defined as the time from the onset of the P wave to the start of the QRS complex. The PWD is the duration between those points measured in the DII lead of a 12-lead ECG, in milliseconds. Two independent cardiologists assessed these parameters. PWDI was calculated by dividing the PWD by the PR interval in the DII lead of 12-lead ECG (Figures 1 A–C). P-wave dispersion (Pdisp) is the difference between the maximum and minimum PWD on a 12-lead ECG. First-degree (partial) interatrial block (IAB) was determined with two previously defined criteria [12]: (a) P wave of 120 ms or more, usually bimodal, which is especially visible in leads I, II, or III; and (b) the P-wave morphology in V1 presenting a P-wave negative mode. Third-degree (advanced) IAB was determined with two previously defined criteria (9): (a) P-wave duration 120 ms or more; and (b) the morphology of P wave is usually bimodal in leads I, and AVL, and biphasic in leads II, III, and AVF, and in V1 and V2. Echocardiographic examinations were performed using an Epiq 7 (Philips Healthcare, DA Best, Netherlands) echocardiography system before CRT implantation. EF, left ventricle diastolic diameter (LVDD), left ventricle systolic diameter (LVSD), left atrium diameter (LAD), left atrium area (LAA), left atrium volume (LAV), and left atrium volume index (ILAV) were measured and recorded. Left atrium volume index (ILAV) was calculated as LAV divided by the body mass index. The interobserver compatibility was 96% in these measurements.

Figure 1

Demonstration of P-wave duration index on surface ECG in three different patients with cardiac resynchronisation therapy

https://amsad.termedia.pl/f/fulltexts/108963/AMS-AD-4-36749-g001_min.jpg

Cardiac resynchronisation therapy device implantation

The CRT-D devices used were manufactured by Medtronic, Inc. The coronary sinus lead (Medtronic Inc., Minneapolis, MN, USA) was placed in the basal or mid-segment of a lateral or posterior vein. The right atrial lead (Medtronic Inc., Minneapolis, MN, USA) was placed in the right atrial appendage, and the right ventricular lead (Medtronic Inc., Minneapolis, MN, USA) was placed in the mid-septum or apex. Patients with sinus rhythm were set to DDD-mode (lower rate limit 50) to achieve atrial synchronous biventricular pacing. Devices were programmed with pacing mode DDD to maximise biventricular pacing. VV delay was set nominally at 0 ms.

Device and clinical evaluation, silent AF definitions

Device interrogations were performed 1, 6, and 12 months after implantation and then also every 6 months. Device atrial stimulation/sense parameters, atrial lead impedance, percentages of atrial and ventricular pacing, automatic mode switch episodes, and noise episodes were recorded. The AF attacks that lasted for at least 30 s with no symptoms were accepted as silent AF (Figure 2). Every arrhythmia in the device memory was interpreted by two experienced physicians. A clinical evaluation was also performed including symptoms, outpatient or emergency department admissions, changes in antiarrhythmic and antithrombotic treatment, ECG documentation of AF, and mortality. Patients with these conditions were accepted as overt AF and excluded from the study (14 patients).

Figure 2

Silent atrial fibrillation episode from intracardiac EGM record

https://amsad.termedia.pl/f/fulltexts/108963/AMS-AD-4-36749-g002_min.jpg

Statistical analysis

Variables were divided into categorical and continuous groups. Categorical variables were expressed as numbers and percentages. The χ2 test was used to analyse categorical variables. Continuous variables were shown as mean and standard deviation. The Kolmogorov-Smirnov test was used to determine whether continuous variables had normal distribution. Normally distributed variables were analysed with the independent samples t-test. Non-normally distributed variables were analysed with the Mann-Whitney U test. Independent predictors for silent AF were determined by binomial logistic regression analysis using p < 0.05 variables. Receiver operating characteristic (ROC) analysis was used to calculate cut-off, sensitivity, and specificity values of the independent silent AF predictors. The SPSS for Windows 20.0 Program (SPSS, Chicago, IL, USA) was used for statistical analysis. A p-value < 0.05 was considered to be statistically significant.

Results

Patients were separated into two groups: “with silent AF” and “without silent AF”. The without silent AF group comprised 121 patients (mean age: 62.9 ±8.7 years, 62% male). The with silent AF group included 60 patients (mean age: 67.9 ±9.7 years, 60% male). The mean follow-up period was 30.2 ±10.8 months. The first silent AF attack was detected 34 days after CRT implantation. The mean silent AF detection time was 155 ±112 days. The mean number of attacks was 1.8 ±0.5, and the longest attack duration was one 1 h 20 min. Atrial high rate episode was detected in 16 patients. There were no inappropriate shocks on routine CRT-D controls. The silent AF group had significantly higher mean age (p = 0.001). We found no other significant variable in the demographics, medications, and laboratory results (Table I). PR duration was significantly longer in the without silent AF group (p = 0.001). Patients with first-degree IAB and PWDI values were significantly higher in the with silent AF group (p-values were 0.001 and < 0.001, respectively). Other ECG and echocardiographic findings were similar (Table II). Age (OR = 1.073, 95% CI: 1.028–1.119, p = 0.001) and PWDI (OR = 1.053, 95% CI: 1.028–1.078, p < 0.001) were detected as independent predictors for silent AF in the binomial logistic regression analysis (Table III). PWDI cut-off, sensitivity, and specificity values were determined for the prediction of silent AF in the ROC analysis (AUC = 0.701, p < 0.001, Figure 3).

Table I

Comparison of patients’ demographics, medications, and laboratory findings

ParameterPatients with silent AF (n = 60)Patients without silent AF (n = 121)P-value
Age [years]67.9 ±9.762.9 ±8.70.001
Male gender, n (%)36 (60.0)75 (62.0)0.796
Systolic blood pressure [mm Hg]120.6 ±16.0121.1 ±17.10.878
Diastolic blood pressure [mm Hg]77.1 ±11.276.2 ±10.70.968
Pulse [beats/min]76.4 ±12.178.3 ±10.90.297
BMI [kg/m2]26.3 ±3.826.8 ±3.20.440
Smoking, n (%)9 (15.0)17 (14.0)0.864
DM, n (%)27 (45.0)53 (43.8)0.879
HT, n (%)38 (63.3)66 (54.5)0.260
HPL, n (%)35 (58.3)52 (43.0)0.052
Ischaemic CMP, n (%)25 (41.7)51 (42.1)0.951
ACE, n (%)43 (71.7)75 (62.0)0.198
ARB, n (%)10 (16.7)25 (20.7)0.522
β-Blocker, n (%)55 (91.7)113 (93.4)0.673
Furosemide, n (%)55 (91.7)104 (88.5)0.268
Spironolactone, n (%)44 (36.4)77 (63.6)0.857
Ivabradine, n (%)14 (23.3)21 (17.4)0.338
Digoxin, n (%)18 (30.0)26 (21.5)0.209
ASA, n (%)35 (58.3)75 (62.0)0.636
WBC [µl]8.2 ±2.48.2 ±2.30.962
Htc (%)37.8 ±4.538.7 ±5.20.284
BUN [mg/dl]55.6 ±34.250.5 ±30.30.302
Cr [mg/dl]1.1 ±0.51.3 ±1.20.287
Na [mmol/l]137.4 ±3.9137.1 ±4.10.654
K [mmol/l]4.6 ±0.64.6 ±0.50.832
Total cholesterol [mg/dl]180.2 ±46.9166.6 ±43.80.056
LDL [mg/dl]113.1 ±34.1105.5 ±35.60.169
HDL [mg/dl]38.5 ±9.637.9 ±13.30.780
Triglyceride [mg/dl]143.8 ±74.4163.2 ±102.30.149
Hs-CRP [mg/l]2.3 ±2.62.4 ±2.90.782
Uric acid [mg/dl]7.1 ±2.26.9 ±2.20.607
NT-proBNP [pg/ml]677.7 ±579.3612.1 ±654.40.510
T4 [ng/dl]1.3 ±0.21.3 ±0.30.626
TSH [uIU/dl]1.9 ±1.21.9 ±1.50.803

[i] AF – atrial fibrillation, BMI – body mass index, CMP – cardiomyopathy, DM – diabetes mellitus, HT – hypertension, HPL – hyperlipidaemia, ACE – angiotensin-converting enzyme, ARB – angiotensin receptor blocker, ASA – acetylsalicylic acid, BUN – blood urea nitrogen, Cr – creatinine, HDL – high density lipoprotein, Hs-CRP – high-sensitivity C-reactive protein, Htc – haematocrit, IQR – interquartile range, LDL – low-density lipoprotein, TSH – thyroid-stimulation hormone, NT-proBNP – N-terminal brain natriuretic peptide, WBC – white blood cells.

Table II

Comparison of electrocardiographic and echocardiographic findings

ParameterPatients with silent AF (n = 60)Patients without silent AF (n = 121)P-value
EF (%)25.5 ±5.924.9 ±5.90.540
LVDD [mm]59.5 ±9.660.2 ±10.20.655
LVDS [mm]59.5 ±9.660.2 ±10.20.655
LAD [mm]42.1 ±4.142.5 ±4.40.508
LAA [mm2]21.1 ±4.321.8 ±4.10.287
LAV [mm3]82.2 ±18.982.0 ±18.30.959
ILAV [ml/m2]45.7 ±11.643.8 ±10.30.253
QRS [ms]151.5 ±17.3152.3 ±16.80.762
PR [ms]141.2 ±17.9157.0 ±27.8< 0.001
PWD [ms]112.4 ±10.6108.3 ±13.40.03
First degree IAB, n (%)20 (%33.6)16 (13.2)0.001
Pdisp [ms]32.8 ±15.730.3 ±11.20.540
PWDI0.81 ±0.140.70 ±0.13< 0.001

[i] AF – atrial fibrillation, EF – ejection fraction, ILAV – indexed left atrial volume, LVDD – left ventricular end diastolic diameter, LAD – left atrial diameter, LAV – left atrial volume, Pdisp – P-wave dispersion, PWD – P-wave duration, PWDI – P-wave duration index.

Table III

Independent predictors for silent AF

ParameterOdds ratio95% confidence intervalP-value
Age1.0731.028–1.1190.001
PWD0.9880.954–1.0230.489
PR0.9480.871–1.0320.216
PWDI1.0531.028–1.078< 0.001

[i] PWD – P-wave duration, PWDI – P-wave duration index.

Figure 3

ROC analysis to determine sensitivity and specificity of P-wave duration index for silent AF

https://amsad.termedia.pl/f/fulltexts/108963/AMS-AD-4-36749-g003_min.jpg

Discussion

The most important finding of our study is the statistically significant relation between PWDI and silent AF. When the PWDI cut-off value was taken as 0.67, the specificity was 81.7% and the sensitivity was 51.4%. Also, age is another significant factor in silent AF development.

Silent AF can be determined incidentally from an inpatient visit, a thorough physical examination, or preoperative assessments. Silent AF patients can sometimes also have AF complications like stroke or congestive heart failure [13]. These patients can be asymptomatic, but it should not be interpreted as there not being any AF complications. Two large studies emphasised the prognostic value and told that silent AF had the same risk as symptomatic AF [14, 15]. It was reported that the 37% yearly incidence of AF in pacemaker-implanted patients and anticoagulant usage was less than expected (58%) despite 77% of patients having CHADS2 score ≥ 2 [16]. We collected optimal rhythm records because our patient group had CRT-D devices. Silent AF was found in 61 (33.7%) patients. The silent AF probability was higher than normal because all of our patients had HF. CHA2DS2-VASc score may be calculated, and anticoagulant therapy may be initiated in suitable patients. It is essential to identify silent AF and initiate the anticoagulant therapy before any complications, because the mortality and morbidity are the same as for symptomatic AF. Silent AF-detected patients are at higher risk of stroke and mortality due to HF and AF.

Remodelling starts with the sodium and calcium channels of the left atrium and pulmonary venous tissue cells in the setting of inflammation and oxidative parameters. Electrical stability starts to decrease, and irregular electrical activity, called atrial heterogeneity, starts to happen. Fibroblast proliferation, inflammation, and apoptosis start to develop as predisposing factors of AF [17]. The investigators described Bayes syndrome, which is characterised by interatrial conduction delay or block [18]. According to them, it is predisposing for the supraventricular arrhythmias to have PWD ≥ 120 ms in DII, DIII and aVF leads. Third-degree IAB (PWD ≥ 120 ms and biphasic P wave) are seen frequently in the elderly even when there is no LAE [19]. Also, it has been shown as a marker of AF, cardiovascular, and all-cause mortality [20]. In studies advanced IAB is not found commonly in the general population but reported as a risk factor for AF. First-degree IAB frequency was 33% in our silent AF patients [21]. It was not an independent factor for AF, but it is significantly high in the silent AF group. It is also compatible with previous studies.

The P-wave duration reflects the distance of electrical activity from the sinus node to the atrioventricular junction. If the distance is long, then the PWD length is approximately the same amount. Prolonged PWD was found to be significantly related to AF in the patients over 60 years old according to the Framingham study [22]. Some researcher found that P-wave variance is related to paroxysmal AF [23]. They claimed that the increased P-wave variance reflects the non-homogeneous spreading of sinus waves in the atrium. P-wave dispersion is a risk factor for AF and projects the atrial electrical heterogeneity. It is said that increased Pdisp is a risk factor for the degeneration of paroxysmal AF to persistent AF [24]. All of our patients had HF. All heart chambers were dilated in these patients. Left atrium sizes were also increased. Therefore, both PWD and Pdisp were higher in the silent AF group, but there was no statistical significance. Even these two parameters were determined higher than the normal population; we do not think that they will be predictors for AF in HF patients. Thus, PWD and Pdisp cannot be used as predictors of AF in our patients. There should be more sensitive markers than PWD and Pdisp for HF patients with silent AF.

Some parameters, such as atrioventricular delay (A-V delay) and interventricular delay (V-V delay), can be adjusted via the CRT-D device. The PR interval will be prolonged with the increased A-V delay. Eventually, this will change the PWDI value. Therefore, we excluded patients with atrial pacing. β-blockers are basically effective over the A-V node. There was over 90% β-blocker usage in both of our groups, and there was no statistical difference. We thought that the β-blocker effect over PWDI was the same in both groups. We also consider that increasing the β-blocker dose will result in the prolonged P-R interval and decreased PWDI value. Thus, silent AF attacks may be diminished.

In a recent study, it was reported that PWDI was a marker for the recurrence in cryoballoon ablation applied patients, and it was found to be relative to the LAV [11]. We found a statistically significant relationship between PWDI and silent AF. Also, it could determine silent AF with relatively high specificity. In our opinion, PWDI is more sensitive for the prediction of silent AF than PWD and Pdisp because it is a ratio of two parameters. Silent AF is diagnosed incidentally, so PWDI can be useful for protection from stroke and mortality in these patients. We think that the calculation of PWDI should be applied after the CRT-D implantation, as our patients. We consider that if we can reduce PWDI value under the cut-off limits by changing the A-V delay or using β-blocker therapy, then silent AF attacks might be diminished.

PR interval, P-wave axis, maximum area and duration, terminal force, and Pdisp are defined as P-wave indices, and they are affected by the patients’ current situation [25]. It was reported in a study that only PR interval is consistent and all other parameters are variable in the 1–2 weeks of periodical ECGs. It can be misleading to use only one of these variable parameters when predicting the patient’s clinical situation. We think it can be more sensitive to use the ratio of at least two parameters.

There were several limitations to our study. The patient number was relatively low compared to other studies [26]. P-wave axis and area, which reflects the atrial heterogeneity, were not calculated. Calculated ECG parameters were not correlated with other ECGs. There is a clear need for randomised studies including more patients, in order to show whether PWDI is a predictor for silent AF.

In conclusion, PWDI is significantly associated with silent AF in patients with CRT-D. Silent AF risk can be determined and diminished with beta-blocker therapy or prolongation of A-V delay. Physicians can adjust A-V delay, and so may reduce silent AF in CRT patients. Therefore, mortality and morbidity may be reduced in these patients.