Total loss of flow in the tortious left anterior descending during coronary intervention due to severe accordion effect

Ibrahim Kocayigit
,
Mustafa Tarık Ağaç

Arch Med Sci Atheroscler Dis 2019; 4: e180–e182
Online publish date: 2019/07/22
Article file
- Total loss.pdf  [0.23 MB]
Get citation
ENW
EndNote
BIB
JabRef, Mendeley
RIS
Papers, Reference Manager, RefWorks, Zotero
AMA
APA
Chicago
Harvard
MLA
Vancouver
 
 

Accordion phenomenon is a guide-wire-induced pseudolesion observed during the course of percutaneous coronary intervention (PCI) in tortuous vessels. This condition is usually seen as a consequence of the straightening effect and shortening of the tortuous artery precipitated by a stiff guidewire during coronary interventions [1]. Sometimes it leads to unnecessary intervention by inexperienced operators. Rarely this phenomenon can cause ischaemia and haemodynamic compromise due to the diminished or total loss of flow if not managed promptly [2]. Here we present a patient with non-ST segment elevation myocardial infarction (NSTEMI), who developed multiple pseudolesions in the tortuous left anterior descending coronary artery (LAD) during PCI.

A 59-year-old female with a history of hypertension and smoking presented to emergency department with chest pain. The patient was transferred to a coronary care unit after being diagnosed as NSTEMI. Early invasive strategy was planned because the patient had high-risk criteria. Coronary angiography via a right radial approach showed severe tortuosity in the LAD and right coronary artery, and severe stenotic lesion in the distal part of the LAD (Figures 1 and 2). Coronary angioplasty of the LAD was decided upon. The left main coronary ostium was engaged by a 6-F 4 Judkins (Cordis, Johnson& Johnson, Miami, FL, USA) guiding catheter. A 0.014-inch hi-torque balance middleweight (Abbott Vascular, Santa Clara, CA, USA) floppy guidewire was advanced across the stenosis. Control angiography showed straightened vessel with multiple filling defects and lesions in the mid segment of the LAD and total loss of the distal flow (Figure 3) while the patient had severe chest pain. Intracoronary nitrate was administrated in order to clarify the possibility of coronary spasm, but the angiographic appearance of the LAD did not change. Then we predilated the lesion using a 1.5 × 15 mm balloon (Invader, Alvimedica, Turkey), and a 2.75 × 18 mm drug-eluting stent (Xience, Abbott Vascular, Santa Clara, CA, USA) was deployed after predilatation (Figures 4 and 5). After successful stent deployment the guidewire was removed, and angiography showed complete resolution of the pseudolesions and recovered distal flow (Figure 6).

Figure 1

The coronary angiography showed severe tortuosity in the LAD and critical stenosis in the distal part

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g001_min.jpg
Figure 2

The coronary angiography showed severe tortuosity in the RCA without any stenosis

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g002_min.jpg
Figure 3

After advancing the guidewire, the control angiography showed straightened vessel with multiple filling defects and lesions in the mid segment of the LAD and total loss of the distal flow

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g003_min.jpg
Figure 4

The lesion was predilatated with a 1.5 × 15 mm balloon

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g004_min.jpg
Figure 5

A 2.75 × 18 mm drug-eluting stent was deployed after predilatation

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g005_min.jpg
Figure 6

After successful stent deployment the guidewire was removed, and angiography showed complete resolution of the pseudolesions and recovered distal flow

/f/fulltexts/AMSAD/37276/AMS-AD-4-37276-g006_min.jpg

Accordion phenomenon during coronary intervention is a rare condition. This condition can be inappropriately identified as coronary spasm or dissection, which may falsely lead to unnecessary stenting [3]. It is more predictable in tortuous coronary arteries, and it can cause reversible narrowing and transient transmural myocardial ischaemia and rarely total loss of the distal flow in the presence of stenotic lesions [2, 4]. It is important to identify such iatrogenic pseudocomplications because they are generally benign and can be managed uneventfully by pulling back the guidewire and re-establishing of the coronary geometry.

Conflict of interest

The authors declare no conflict of interest.

References

1 

Alvarez JA, Leiva G, Manavella B, Cosentino JJ , authors. Left main crumpling during left anterior descending angioplasty: hitherto unreported location for the “accordion effect”. Catheter Cardiovasc Interv. 2001. 52:p. 363–7

2 

Gavrielatos G, Pappas LK, Anthopoulos P, Salachas A, Ifantis G, Antonellis I , authors. Severe accordion effect: myocardial ischemia due to wire complication during percutaneous coronary intervention: a case report. Cases J. 2008. 1:p. 138

3 

Davidavicius G, Manoharan G, De Bruyne B , authors. The accordion phenomenon. Heart. 2005. 91:p. 471

4 

Kilic ID, Yildiz BS, Alihanoglu YI, Evrengul H , authors. The accordion phenomenon in the left anterior descending coronary artery. Tex Heart Inst J. 2014. 41:p. 562–3

Copyright: © 2019 Termedia & Banach. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2019 Termedia Sp. z o.o. All rights reserved.
Developed by Bentus.
PayU - płatności internetowe