eISSN: 2299-0054
ISSN: 1895-4588
Videosurgery and Other Miniinvasive Techniques
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2019
vol. 14
 
Share:
Share:
Cardiac surgery
abstract:
Original paper

Transapical beating heart mitral valve repair with the NeoChord system: early outcomes of a single-center experience

Krzysztof Wróbel
,
Katarzyna Kurnicka
,
Marcin Zygier
,
Dariusz Zielinski
,
Wojciech Dyk
,
Ryszard Wojdyga
,
Zbigniew Juraszynski
,
Piotr Pruszczyk
,
Andrzej Biederman

Videosurgery Miniinv 2019; 14 (2): 320–325
Online publish date: 2019/02/05
View full text Get citation
 
PlumX metrics:
Introduction
Trans-apical beating heart off-pump mitral valve (MV) repair is a novel surgical technique for treating mitral regurgitation (MR) caused by degenerative flail/prolapse (DLP).

Aim
To present early outcomes of a single-center experience with transapical beating heart mitral valve repair with the NeoChord system.

Material and methods
Thirty-seven patients with severe symptomatic MR were treated with the NeoChord technique between September 2015 and December 2018 (78% men; mean age: 62.3 ±13.4 years). We evaluated standard cardiac surgery perioperative complications as well as those related to the NeoChord technique as well as early surgical success as defined by the reduction of MR to less than moderate by implantation of at least 2 neochordae.

Results
During this series we had no hemodynamic instability due to bleeding or arrhythmia. There were no transapical technique-related adverse events such as a leaflet perforation or tear, a major native chord rupture, which would require implantation of a new chord, ventricular apex rupture, or left atrial perforation. There were no major adverse events including death, stroke or acute myocardial infarction. Nine (24%) patients developed an episode of perioperative atrial fibrillation. We were able to conclude the operation in 98% of our patients with less than moderate MR. One (2%) patient had moderate MR at the conclusion of the operation.

Conclusions
Trans-apical off-pump MV repair with the NeoChord system is a safe, minimally invasive procedure, with few minor complications. In well-selected candidates it provides successful treatment of degenerative MR. Results are anatomy dependent, so preoperative patient selection is crucial.