eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2019
vol. 15
 
Share:
Share:
abstract:
Original paper

Comparison of drug-eluting and bare metal stents for extracranial vertebral artery stenting

Damian R. Maciejewski
1
,
Piotr Pieniazek
1, 2, 3
,
Lukasz Tekieli
1
,
Piotr Paluszek
2
,
Tadeusz Przewlocki
1, 2, 3
,
Tomasz Tomaszewski
4
,
Roman Machnik
2
,
Mariusz Trystula
2
,
Jacek Legutko
1
,
Anna Kablak-Ziembicka
1

1.
Department of Interventional Cardiology, Institute of Cardiology, Jagiellonian University Medical College, John Paul II Hospital, Krakow, Poland
2.
Department of Vascular Surgery and Endovascular Interventions, John Paul II Hospital, Krakow, Poland
3.
Department of Cardiac and Vascular Diseases, Jagiellonian University, John Paul II Hospital, Krakow, Poland
4.
Department of Neurology and Stroke Unit, John Paul II Hospital, Krakow, Poland
Adv Interv Cardiol 2019; 15, 3 (57): 328–337
Online publish date: 2019/09/18
View full text Get citation
 
Introduction
Drug-eluting stents of the first (DES I) and second generation (DES II) proved superior to bare metal stents (BMS) in the coronary territory. However, there are limited data on whether they have any advantage over BMS in vertebral artery stenosis (VAS).

Aim
To compare outcomes of DES (DES I, DES II) and BMS in the treatment of symptomatic extracranial VAS.

Material and methods
During 13-year study period (2003–2016), 392 consecutive patients underwent VAS angioplasty in 428 arteries, including implantation of 148 DES (DES I: 21; DES II: 127 lesions), and 280 BMS.

Results
The technical success rates for DES and BMS groups were 96.7% and 94.6% (p = 0.103), with similar periprocedural complication rates (1.4% vs. 2.2%; p = 0.565). VAS degree was reduced from 86 ±9.7 to 2.7 ±5.0% in DES (p < 0.001) and from 84.1 ±9.4 to 4.3 ±6.9% in BMS (p < 0.001). Angiography confirmed in-stent restenosis/occlusion (ISR/ISO) 50–99% in 53 (14.2%) and 21 (5.6%) out of 373 patients (409 arteries) with at least 6-month follow-up. ISR/ISO rates were similar in DES vs. BMS (22.8% vs. 19.4%; p = 0.635), as well as in DES I vs. DES II (6/19; 31.6% vs. 25/92; 27.2%, p = 0.325). Stainless steel (24/135; 17.8%) and cobalt-chromium (23/121;19%) BMS had significantly lower incidence of ISR/ISO, as compared to platinum-chromium (7/18; 38.9%), p = 0.034. ISR/ISO was associated with age (p = 0.01) and CRP level > 5 mg/l (p = 0.043), while greater stent length was associated with ISR only in the DES group (p = 0.024).

Conclusions
Our results do not support significant differences in ISR/ISO rates between DES and BMS, although differences between particular stent types and ISR rates require further investigation.

keywords:

drug-eluting stent, in-stent restenosis, bare metal stent, vertebral artery stenting

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.