eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2024
vol. 20
 
Share:
Share:
abstract:
Review paper

Percutaneous left atrial appendage closure with the Watchman device: a systematic review

Jakub Maksym
1
,
Marcin Grabowski
1
,
Tomasz Mazurek
1

1.
First Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
Adv Interv Cardiol 2024; 20, 1 (75): 18–29
Online publish date: 2024/03/15
View full text Get citation
 
Atrial fibrillation (AF) is the most commonly observed arrhythmia in the world and its prevalence increases with age. The main and most severe complication of AF is ischemic stroke. Oral anticoagulation (OAC) therapy is the standard of care for stroke prevention in the high risk population. Initiation of this treatment is associated with a substantial risk of bleeding complications. Moreover, there is a group of patients who cannot tolerate OAC. In patients with AF the left atrial appendage (LAA) is the main source of thrombus formation. Percutaneous left atrial appendage closure (LAAC) has become an important non-pharmacological intervention for stroke prevention in patients with non-valvular AF. The procedure aims to reduce the risk of thromboembolism without increasing the risk of bleeding. Over the last few years, the safety and long-term efficacy of the procedure in specific populations have increased and more patients are being treated. The Watchman device is the most studied device in this field. Randomized controlled trials demonstrated non-inferiority of percutaneous left atrial appendage closure using the WATCHMAN 2.5 device to OAC (Boston Scientific, Marlborough, MA, USA). The new generation device, WATCHMAN FLX, was introduced and its use was associated with fewer safety events and a higher success rate of effective appendage closure. Nevertheless, several unsolved problems remain, including device-related thrombosis, the post-LAAC antithrombotic regimen, and peri-device leakage. This review will focus on LAAC with the Watchman device for stroke prevention in AF patients. Current status, available literature, clinical safety and efficacy will be summarized.
keywords:

atrial fibrillation, left atrial appendage closure, device-related thrombus, peri-device leak

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.