eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
1/2024
vol. 20
 
Share:
Share:
Image in intervention

Radial access versus distal radial access: the vote for use of ultrasonography?

Bogumił Ramotowski
1
,
Anna Żuk
1
,
Paweł Lewandowski
1
,
Tomasz Słomski
1
,
Paweł Maciejewski
1
,
Andrzej Budaj
1

1.
Department of Cardiology, Centre of Postgraduate Medical Education, Warsaw, Poland
Adv Interv Cardiol 2024; 20, 1 (75): 112–114
Online publish date: 2024/03/15
Article file
- radial access (2).pdf  [0.14 MB]
Get citation
 
 

In recent years, radial access (RA) has been recommended in guidelines as the preferred access for any percutaneous coronary intervention (PCI). The novel transradial access site, distal radial access (DRA), has gained popularity owing to improved patient and operator comfort, and faster hemostasis with shorter artery gauze compression. Despite the emerging technique and increasing amount of data in favor of preprocedural ultrasonography (pre-US) including DRA [1], the choice of the artery is still based on pulse recognition.

We present an illustrative case of a 75-year-old patient with typical exercise chest pain and a history of anterior myocardial infarction treated with PCI. The patient was admitted for scheduled coronary angiography (CA) via the right transradial approach. The radial pulse was palpated, typically 2 cm proximal to the radial styloid process of the right hand. The radial artery was punctured and cannulated with the standard 6F sheath. Due to pain during engagement, an arteriography of the forearm was taken, revealing a sheath in the narrow (1.5 mm) palmar superficial branch of the radial artery, and a wide radial artery in the anatomical snuffbox (Figure 1 A). CA revealed a critical distal right coronary artery (RCA) lesion and an intermediate left anterior descending (LAD) artery lesion. PCI of the distal RCA with drug-eluting stent (DES) implantation was performed, after the procedure, radial artery gauze compression was used, and the patient was scheduled for the next stage procedure with assessment of the LAD. After 1 month, the pulse in the right radial artery at a typical point was not palpable, whereas the pulse in the snuffbox was palpable. Doppler ultrasonography of the right upper extremity revealed a closed superficial palmar branch which was completely asymptomatic clinically with good flow in the main radial artery in the snuffbox (Figure 1 C, at the top) and ulnar artery (Figure 1 C, at the bottom). The procedure was successfully performed with 6F standard sheath from the snuffbox. Angiography of the upper limb circulation was performed (Figure 1 B), which confirmed a closed superficial palmar branch. Hemostasis was achieved using standard radial artery gauze compression. Ultrasonography after 2 weeks revealed good flow in the main radial artery in the snuffbox, with a lack of flow in the superficial palmar branch.

Figure 1

A – Arteriography of cannulated superficial palmar branch. B – Radial artery cannulated in snuffbox. C – Doppler ultrasonography of the right upper extremity with a closed superficial palmar branch, flow in radial artery at the top, flow in ulnar artery at the bottom. D – The palmar arch scheme

/f/fulltexts/PWKI/52667/PWKI-20-52667-g001_min.jpg

Knowledge of the arterial anatomy of the forearm, size, and abnormalities prior to invasive procedures can assist in preventing complications. The superficial palmar branch is usually smaller than 1.7 mm branch diverging lower than the puncture site, not considered to be an access artery; however, in this rare particular case, the superficial palmar branch diverged untypically high [2], with a good pulse recognition initially resulting in misleading puncture. Pre-US before RA is not a routine procedure, but we previously reported the usefulness of ultrasound in assessing the impact of pre-US selection of the dominant forearm artery on the incidence of vascular complications and also on the lower incidence of hand strength reduction [3, 4]. Ultrasound-guided larger diameter artery access was associated with a lower incidence of vascular complications. This case supports pre-US application in selecting between the radial and distal radial approaches.

Conflict of interest

The authors declare no conflict of interest.

References

1 

Achim A, Péter OÁ, Kákonyi K, et al. The role of ultrasound in accessing the distal radial artery at the anatomical snuffbox for cardiovascular interventions. Life (Basel) 2022; 13: 25.

2 

Jyothsna P, Nayak SB, Mohandas Rao KG, et al. High level branching and very superficial course of radial artery in the anatomical snuffbox: its clinical and surgical implications. OA Case Rep 2013; 2: 66.

3 

Lewandowski P, Zuk A, Slomski T, et al. Impact of the use of a larger forearm artery on the efficacy and safety of transradial and transulnar access: a randomized trial with preprocedural ultrasonography. J Clin Med 2020; 9: 3607.

4 

Lewandowski P, Zuk A, Slomski T, et al. The impact of using a larger forearm artery for percutaneous coronary interventions on hand strength: a randomized controlled trial. J Clin Med 2021; 10: 1099.

Copyright: © 2024 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 