Journal of Stomatology

AI-assisted and visual shade assessment of tooth color changes following diode laser–activated bleaching: a preliminary clinical study

  1. Department of Periodontology and Oral Implantology, NIMS Dental College and Hospital, Jaipur, India

  2. Department of Conservative Dentistry and Endodontics, Subharti Dental College and Hospital, Meerut, India

J Stoma 2026; 79, 4: 279-288

Data publikacji online: 2026/11/10
Article file
01435-AI-assisted.pdf

Introduction

Dental aesthetics can influence social perception, psychological well-being, and self-confidence. Among the various aesthetic concerns, tooth discoloration is common, arising from intrinsic anomalies, fluorosis, ageing, and extrinsic factors such as diet and lifestyle. With growing demand for minimally invasive aesthetic treatments, vital tooth bleaching has become the a widely used option due to its ability to improve shade while preserving natural tooth structure [1, 2].

Hydrogen peroxide (HP) remains the most widely used bleaching agent because of its strong oxidizing capacity, which degrades chromogenic compounds within enamel and dentin. Its activity can be enhanced through thermal or light activation, with diode lasers being among the most commonly investigated methods [2-4]. Studies have reported that light-activated bleaching can improve outcomes, although high concentrations of HP combined with thermal activation may cause transient enamel changes and sensitivity [1, 3]. While saliva helps counteract some alterations, concerns about enamel microhardness and pulp safety persist, especially with heat-producing devices [5].

A further challenge in bleaching research is the accurate evaluation of color change. Conventional shade guides, such as the VITA Classical system, remain widely used but are limited by subjectivity and variability [6, 7]. More advanced methods – including spectrophotometry and digital imaging – offer better standardization but are not always practical in daily clinical settings [6]. Recently, artificial intelligence (AI)-driven tools such as Matisse AI have been developed to provide objective, reproducible, and predictive colorimetric analysis of tooth shade parameters, offering an innovative alternative to traditional visual assessment [7-10].

Despite numerous clinical studies on HP bleaching, the literature remains limited in two key aspects: (1) the lack of consistent, objective, and reproducible evaluation methods beyond conventional shade guides, and (2) insufficient in vivo evidence on the clinical utility of AI-based systems for colorimetric assessment in bleaching. Previous reports have either relied solely on visual methods prone to subjectivity or on costly spectrophotometric devices not feasible for routine practice.

Recently, Awdaljan et al. [11] introduced a novel AI-assisted approach to dental color reproduction, demonstrating the reliability of digital platforms such as Matisse in standardizing shade determination for indirect restorations. This advancement highlights the potential of AI to overcome traditional limitations in shade analysis, yet its application in vital tooth bleaching remains underexplored.

Objectives

Therefore, the present study was designed to address these gaps by evaluating the efficacy of 40% HP bleaching activated by an 810 nm diode laser, with outcomes assessed using both the VITA Classical Shade Guide and an AI-driven digital color detection platform (Matisse AI). We observed shade changes following a bleaching protocol that included diode laser activation, and AI-based colorimetric analysis provides a more objective and reproducible assessment of tooth shade change compared to conventional methods.

Material and methods

This was designed as a preliminary observational clinical study to evaluate tooth color changes following in-office tooth bleaching using 40% HP activated with an 810 nm diode laser. The protocol adhered to the Declaration of Helsinki and institutional ethical standards, and written informed consent was obtained from all participants before inclusion.

The study sample of 100 patients was selected based on feasibility and sample sizes reported in previous clinical studies of in-office bleaching. While a formal a priori sample size calculation was not performed, previous studies indicate that a minimal clinically important difference (MCID) for ΔE in dental aesthetics is approximately 3.3 units [12]. With an expected post-treatment ΔE improvement of 8-10 units and a standard deviation of 4 units, the present sample provides at least 80% power at a 5% significance level to detect a clinically meaningful color change using paired statistical analysis.

Patients, aged between 20 and 50 years, presenting with anterior tooth discoloration were recruited for the study. Inclusion criteria required the absence of active dental caries, a history of smoking, or restorative materials on the labial surfaces of the anterior teeth. Patients with a history of bleaching treatment within the preceding 12 months, those presenting with enamel hypoplasia or developmental defects, and individuals diagnosed with periodontal pathology were excluded to maintain sample homogeneity. All participants underwent comprehensive professional prophylaxis before the intervention to standardize baseline oral conditions.

The bleaching protocol involved the application of a chemically activated 40% HP gel (Opalescence, Ultradent, USA) to the labial surfaces of the maxillary and mandibular anterior teeth in a uniform 0.5-1.0 mm thick layer (Figure 1). A light-cured gingival barrier was used to protect adjacent soft tissues from chemical irritation. The dual-barrel syringe system of the bleaching agent ensured fresh mixing of the activator and peroxide immediately before application. The gel was left in contact with the tooth surface for 20 minutes per cycle and activated using an 810 nm diode laser (PICASSO, AMD Lasers, USA), delivering irradiation for 10 seconds per tooth. This procedure was repeated in three consecutive cycles according to the study protocol. Excess gel was carefully removed with suction without water spray to prevent splatter and preserve the gingival barrier. All procedures were performed by a single calibrated operator (R.P.) to reduce variability. All bleaching procedures were performed by the principal operator, who was not involved in the color evaluation phases. Visual shade assessments and Matisse AI–based image analysis were carried out independently by two calibrated colleagues who did not participate in the treatment procedures, and who were blinded to treatment details and clinical information. Thus, those conducting both subjective (VITA) and objective (digital/AI) assessments were blinded to clinical information, thereby reducing the potential for observer bias in outcome assessment (Figure 2).

Visual shade assessment

Visual shade matching was performed with the VITA Classical Shade Guide (VITA Zahnfabrik, Bad Säckingen, Germany). Each shade tab was assigned a numeric rank from 1 (lightest, B1) to 16 (darkest, C4), following the standardized VITA A1-D4 system. Evaluations were conducted under standardized daylight conditions by two independent, calibrated examiners (P.K., R.P.) who were not involved in the bleaching procedures. Before patient recruitment, both examiners underwent calibration sessions using a reference set of clinical images and VITA shade tabs. Inter-examiner agreement was determined by calculating Cohen’s kappa (κ = 0.84). Shade selection was recorded at baseline and post-treatment. Any discrepancies were resolved through consensus discussion.

Digital shade assessment

To complement the visual evaluation, standardized photographic documentation was obtained at baseline and immediately after treatment. Images were captured using a Sony Alpha 6600 DSLR camera (25.2-megapixel sensor, 50-108 mm lens) equipped with twin-flash illumination and cross-polarizing filters to minimize glare. Each frame included a neutral grey reference card (18% reflectance) to enable accurate white balance calibration. All images were acquired in RAW format using manual settings for exposure, ISO, and working distance to ensure reproducibility. Post-processing was performed with automatic color correction disabled. Digital analysis was conducted using the Matisse AI platform (v2.4.2, Matisse Technologies, Germany), which employs convolutional neural network-based segmentation followed by automated conversion to CIELAB color space. The analytical workflow included preprocessing with white balance correction, exclusion of gingival tissues and specular highlights, and extraction of L* (lightness), a* (red–green), b* (yellow–blue), hue, and chroma values. Color difference (ΔEab) was calculated using the standard CIE76 formula: ΔEab = √[(ΔL*)² + (Δa*)² + (Δb*)²].
Comparative analysis of shade changes was performed by assessing ΔE
ab and related colorimetric parameters between baseline and post-treatment images. Predictive modelling algorithms within the platform estimated expected bleaching outcomes based on initial shade, HP concentration, and laser activation parameters.

This dual evaluation approach, combining standardized Vita Shade Guide assessment with Matisse AI-driven analysis, provided a robust, objective, and reproducible framework to assess the clinical efficacy of diode laser-activated HP bleaching. Clinical shade and photographic assessments were conducted at two standardized time points: at baseline (before bleaching), and immediately after treatment (after completion of three laser-activated bleaching cycles).

Safety and adverse events were assessed at baseline, immediately after bleaching, and at follow-up after 1 week, 2 weeks, and 3 weeks. All participants were monitored for tooth sensitivity and pulpal discomfort using a standardized 10-point Visual Analogue Scale (VAS), recorded before and after each bleaching cycle and for 3 weeks. Intrapulpal temperature was not directly monitored during the bleaching procedures. However, the selected laser parameters (810 nm wavelength, 1.5 W, 10 seconds per tooth) align with evidence from previous clinical studies indicating a low risk of significant pulpal heat generation at these settings [13].

Statistical analysis

The statistical analysis was performed using descriptive and inferential statistics. Descriptive statistics, including mean, standard deviation, minimum, maximum, and 95% confidence interval, were calculated for all variables. Pearson’s correlation coefficient was used to assess the relationship between pre- and post-test values. A paired t-test was applied to compare the mean diffe­rences between pre- and post-treatment measurements. One-way ANOVA was used to compare ΔE values among cervical, middle, and incisal regions, followed by post hoc pairwise comparisons where applicable. The c2 test was employed to evaluate the distribution of VITA shade scores before and after treatment. A p-value < 0.05 was considered statistically significant.

Results

A total of 100 participants were included in the final analysis. Pre- and post-treatment colorimetric parameters are summarized below.

Significant post-treatment increases in L* values were observed at the cervical, middle, and incisal regions (p < 0.001 for all regions) (Table 1 and Figure 3). In contrast, a* values did not demonstrate statistically significant changes in any region (p > 0.05). Among the b* parameters, a significant change was observed only in the incisal region (p = 0.017), while cervical and middle regions remained non-significant (p > 0.05). Chroma values showed no statistically significant overall difference (p = 0.951).

Mean pre- and post-treatment differences (Table 2) demonstrated statistically significant increases in L* values in the incisal (5.01 ± 3.39), middle (5.15 ± 3.35), and cervical (4.76 ± 3.17) regions (p < 0.001 for all regions), with an overall mean increase in lightness of 4.97 ± 1.93 (p < 0.001). Significant differences were also observed in chroma (6.94 ± 22.15, p = 0.002) and middle b* values (1.97 ± 9.05, p = 0.032), whereas changes in a* values and cervical and incisal b* values were not statistically significant.

Inter-regional comparison of ΔE values using one-way ANOVA (Table 3) revealed no statistically significant differences among the cervical (10.38 ± 4.73), middle (10.78 ± 4.62), and incisal (9.55 ± 4.08) regions (F = 1.954, p = 0.144). Pairwise comparisons confirmed the absence of significant inter-regional variation (Table 4).

VITA shade distribution demonstrated a significant post-treatment shift (p = 0.001) (Table 5 and Figure 4), with pre-treatment shades predominantly A2 (52%) and B2 (30%), and post-treatment shades predominantly B1 (76%) and A1 (13%).

Baseline and post-treatment L* values and regional ΔE measurements are presented in Table 6. The overall mean L* increased from 77.72 ± 1.71 to 82.70 ± 2.39. The overall mean ΔE was 10.24 ± 2.60.

Shade transition analysis (Table 7) revealed A2–B1 (41%) as the most frequent conversion, followed by B2-B1 (24%). Pearson correlation analysis demonstrated a mo­derate positive correlation between shade change and chroma change (r = 0.362, p = 0.032) and a weak positive correlation between shade change and lightness change (r = 0.225, p = 0.042).

Discussion

The present study evaluated tooth color changes following diode laser-activated bleaching and its quantification using both conventional visual assessment and AI-based digital colorimetry. The findings demonstrated statistically significant increases in tooth lightness following treatment, with color changes exceeding the cited perceptibility and acceptability thresholds. The weak but statistically significant positive correlation observed between VITA shade change and Matisse AI-derived lightness change (r = 0.225, p = 0.042) suggests that visual shade assessment and instrumental colorimetric analysis may capture complementary aspects of tooth color change.

The whitening effect observed was primarily driven by significant increases in lightness (L*) values, whereas chroma and hue changes were less consistent. Dozić et al. [14] demonstrated that instrumental color-measuring devices are particularly sensitive to variations in lightness and reported that L* represents the most responsive parameter in bleaching assessment. Similarly, Möbius et al. [15] reported that laser-assisted bleaching produces pronounced improvements in lightness compared with chromatic coordinates, suggesting that bleaching-related color changes are predominantly reflected in the lightness component of tooth color. The findings of the pre­sent study are therefore consistent with previously reported bleaching characteristics.

The mean overall ΔEab value of 10.24 ± 2.60 exceeded established perceptibility (ΔE = 3.3) and acceptability (ΔE ≈ 5.5) thresholds for dental color differences, indicating that the observed color change was likely to be perceptible and exceeded the cited acceptability threshold [12, 16]. Perez et al. [16] defined clinically relevant CIEDE2000 acceptability limits for dental color diffe­rences, providing a framework for interpreting clinically meaningful color change. Comparable ΔE values following diode laser bleaching have been reported by Saluja et al. [17], who observed significant lightness enhancement using spectrophotometric evaluation, and by Wetter et al. [18], who demonstrated improved bleaching efficacy with diode laser activation compared with non-activated protocols.

The potential benefits of diode laser-assisted bleaching have been investigated in both experimental and clinical investigations. Fornaini et al. [1] analyzed shade change, temperature variation, and HP behavior during laser activation and reported enhanced bleaching efficiency with diode laser systems. Tekce et al. [2] reported sustained whitening outcomes at nine-month follow-up following diode laser-activated bleaching, indicating favorable clinical durability. Furthermore, the systematic review by Kiryk et al. [3] concluded that laser-assisted bleaching may improve whitening outcomes under appropriately selected clinical parameters.

Differences between visual and instrumental shade assessment have long been recognized. Polo et al. [19] demonstrated measurable discrepancies between human visual shade matching and spectrophotometric evaluation, emphasizing the importance of objective verification in clinical color determination. Similarly, Lehmann et al. [20] compared multiple color-measuring devices and highlighted the variability that may occur among instruments, underscoring the need for standardized measurement protocols. The weak correlation observed in the present study between VITA shade change and Matisse AI-derived lightness change is consistent with the possibility that categorical visual shade changes and continuous instrumental color measurements assess related but distinct aspects of tooth color. Joiner and Luo [21] emphasized that visual shade assessment benefits from adjunctive instrumental confirmation to enhance reproducibility.

AI-based systems have increasingly been introduced in dentistry to improve diagnostic precision and standardization. Perez et al. [7] reviewed the applications of
AI in dental practice and highlighted its role in image-based diagnostics and color analysis. Schwendicke
et al. [8] described the expanding application of convolutional neural networks in dental image interpretation. Tabatabaian et al. [10] further emphasized the accuracy and clinical utility of AI systems in restorative dentistry. Additionally, Karcıoğlu et al. [9] reported that machine-learning-based shade classification improves accuracy under varying lighting conditions, thereby reducing metamerism-related discrepancies, while Awdaljan et al. [11] introduced AI-assisted digital color reproduction techniques applicable to clinical dentistry. In a recent systematic review, Shetty et al. [22] concluded that AI-based shade-matching systems demonstrate promising reproducibility and quantitative reliability. Collectively, these findings provide a rationale for investigating the adjunctive role of Matisse AI as a quantitative adjunct to conventional shade assessment.

Biological variability remains an important determinant of bleaching response. Goldstein and Garber [23] identified enamel thickness, intrinsic pigmentation, and baseline tooth shade as major factors influencing whitening outcomes. Llena et al. [24] demonstrated that HP diffusion characteristics, with or without light activation, may also contribute to inter-individual variability in bleaching response. Such bio­logical factors may partly explain the variability observed in chroma and hue measurements in the present investigation.

Thermal safety during laser-assisted bleaching has also been extensively evaluated. Klunboot et al. [5] investigated pulpal temperature changes during diode laser whitening and reported safe thermal limits under controlled conditions. Papadopoulou et al. [13] confirmed that appropriate diode laser power settings maintain biologically acceptable pulp chamber temperature elevations. Petersen et al. [25] further demonstrated clinically controlled intrapulpal temperature increases during diode laser activation. Comparative analyses by Sarkar and Bhandary [26] showed acceptable thermal effects when diode laser systems were compared with LED-based bleaching systems, and Hanna et al. [27] reported favorable safety outcomes with a 450 nm laser system for vital tooth whitening. These findings provide contextual evidence regarding the thermal safety of appropriately selected laser parameters.

Long-term color stability remains a critical factor in bleaching therapy. El-Sayed et al. [28] documented color rebound one year after in-office bleaching procedures, highlighting the importance of extended follow-up. Similarly, Mailart et al. [29] reported one-year outcomes showing that bleaching stability varies by technique and patient-related factors. The short follow-up duration in the present study therefore limits assessment of long-term stability.

Despite the favorable outcomes observed, several limitations should be acknowledged. The absence of a non-laser control group limits the ability to determine the independent additive effect of diode laser activation compared with chemical bleaching alone. Additionally, evaluation of a single bleaching agent, laser wavelength, and imaging protocol restricts extrapolation to alternative clinical systems. Future randomized controlled trials incorporating longer follow-up periods and comparative device analyses are recommended to further validate these findings.

Within the limitations of the present study, diode laser–activated bleaching produced statistically significant increases in tooth lightness and overall color change, primarily driven by increased lightness values. Matisse AI-assisted digital colorimetry provided quantitative measurements of tooth color change and may serve as a complementary adjunct to conventional visual shade assessment in clinical bleaching evaluation.

Future directions

Future investigations should incorporate larger randomized controlled trials with extended follow-up periods to evaluate the long-term stability and potential relapse of bleaching outcomes. Comparative studies involving different bleaching agents, light-activation systems, and AI-based colorimetric platforms are necessary to determine optimal clinical protocols and to enhance cross-system comparability. Furthermore, continued refinement of AI-driven calibration and image-normalization algorithms may help minimize variability in chroma and hue measurements, thereby improving the precision, consistency, and clinical applicability of digital shade-matching technologies.

Conclusions

The present findings demonstrate that diode laser-activated bleaching resulted in statistically significant and clinically perceptible whitening, primarily reflected by increases in tooth lightness, as confirmed by both VITA shade assessment and Matisse AI-derived mean lightness values. Although variability in chroma and hue parameters did not reach statistical significance, these fluctuations may reflect the combined influence of biological tooth characteristics and potential calibration-related variability in image normalization. Overall, Matisse AI-assisted colorimetric analysis provided quantitative measurements of bleaching outcomes; however, potential calibration-related variability suggests that AI-based systems should be employed as complementary tools rather than standalone evaluators, with conventional visual shade assessment remaining an important component of clinical evaluation. Further controlled studies with extended follow-up are warranted to confirm long-term color stability and to further refine AI-assisted bleaching evaluation protocols.

Disclosures

Author contributions: Conceptualization: P.K., R.P.; Methodology: P.K., R.P.; Investigation and data collection: P.K., R.P.; Formal analysis: P.K.; Data curation: P.K., R.P.; Writing – original draft: P.K.; Writing – review and editing: P.K., R.P.; Supervision: R.P.; Project administration: P.K. All authors have read and agreed to the published version of the manuscript.

Funding: None.

Institutional Review Board statement: Not applicable.

Informed consent statement: Not applicable.

Data availability statement: All the data generated or analyzed in this study are included in this manuscript. The data generated in this study may be requested from the corresponding author.

Acknowledgments: None.

Conflicts of interest: The authors declare no conflicts of interest.

AI use statement: None.

References

  1. Fornaini C, Lagori G, Merigo E, Meleti M, Manfredi M, Guidotti R, et al. Analysis of shade, temperature and hydrogen peroxide concentration during dental bleaching: in vitro study with the KTP and diode lasers. Lasers Med Sci 2013; 28: 1-6.
  2. Tekce AU, Yazici R. Clinical comparison of diode laser- and LED-activated tooth bleaching: 9-month follow-up. Lasers Med Sci 2022; 37: 3237-3247.
  3. Kiryk J, Kiryk S, Wójcik W, Domagała D, Królikowska A, Pietruski J, et al. Effectiveness of laser-assisted teeth bleaching: a syste­matic review. Appl Sci 2024; 14: 9219. DOI: 10.3390/app14209219.
  4. Kiomarsi N, Salim S, Sarraf P, Kharazifard MJ, Chiniforush N. Evaluation of the diode laser (810nm,980nm) on dentin tubule diameter following internal bleaching. J Clin Exp Dent 2016; 8: e241-e245. DOI: 10.4317/jced.52666.
  5. Klunboot U, Arayathanitkul K, Chitaree R, Emarat N. The temperature effects of diode laser on pulpal tissues for the teeth whitening treatment. Procedia Eng 2012; 32: 722-726. DOI: 10.1016/j.proeng.2012.02.003.
  6. Herrera LJ, Pulgar R, Santana J, Cardona JC, Guillén A, Rojas I, et al. Prediction of color change after tooth bleaching using fuzzy logic for Vita Classical shades identification. Appl Opt 2010; 49: 422-429.
  7. Perez FC, Pecho OE, Morales JC, Paravina RD, Della Bona A, Ghinea R, et al. Applications of artificial intelligence in dentistry: a comprehensive review. J Esthet Restor Dent 2022; 34: 259-280.
  8. Schwendicke F, Golla T, Dreher M, Krois J. Convolutional neural networks for dental image diagnostics: a scoping review. J Dent 2019; 91: 103226. DOI: 10.1016/j.jdent.2019.103226.
  9. Karcıoğlu AA, Efitli E, Simsek E, Ozdogan A, Karatas F, Senocak T. Machine learning-based tooth shade assessment to prevent metamerism: accurate classification under varying clinical light conditions. Lasers Med Sci 2025; 40: 39. DOI: 10.1007/s10103-025-04297-y.
  10. Tabatabaian F, Vora SR, Mirabbasi S. Applications, functions, and accuracy of artificial intelligence in restorative dentistry: a literature review. J Esthet Restor Dent 2023; 35: 842-859.
  11. Awdaljan MW, Roque JC, Choi J, Rondón LF. Introducing a novel approach to dental color reproduction using AI technology. J Esthet Restor Dent 2024; 36: 1623-1637.
  12. Khashayar G, Bain PA, Salari S, Dozic A, Kleverlaan CJ, Feilzer AJ. Perceptibility and acceptability thresholds for colour differences in dentistry. J Dent 2014; 42: 637-644.
  13. Papadopoulou A, Dionysopoulos D, Strakas D, Kouros P, Kolokitha OE, Tolidis K. Temperature changes in the pulp chamber and bleaching gel during tooth bleaching assisted by diode laser (445 nm) using different power settings. Lasers Med Sci 2023; 38: 209. DOI: 10.1007/s10103-023-03863-6.
  14. Dozić A, Kleverlaan CJ, El-Zohairy A, Feilzer AJ, Khashayar G. Performance of five commercially available tooth color-measuring devices. J Prosthodont 2015; 24: 476-482.
  15. Möbius D, Braun A, Franzen R. Evaluation of tooth color change after a bleaching process with different lasers. Odontology 2024; 112: 872-883.
  16. Perez MDM, Ghinea R, Herrera LJ, Ionescu AM, Pomares H, Pulgar R, et al. Dental ceramics: a CIEDE2000 acceptability thresholds for lightness, chroma and hue differences. J Dent 2011; 39: e37-e44. DOI: 10.1016/j.jdent.2011.09.007.
  17. Saluja I, Shetty N, Shenoy R, Pangal SN. Evaluation of the efficacy of diode laser in bleaching of the tooth at different time intervals using a spectrophotometer: an in vitro study. J Conserv Dent 2022; 25: 166-172.
  18. Wetter NU, Barroso MC, Pelino JE. Dental bleaching efficacy with diode laser and LED irradiation: an in vitro study. Lasers Surg Med 2015; 47: 331-337.
  19. Polo CG, Polo MG, Vinuela AC, Parga JAMV. Differences between the human eye and the spectrophotometer in the shade matching of tooth colour. J Dent 2014; 42: 742-745.
  20. Lehmann KM, Igiel C, Schmidtmann I, Scheller H. Four color-measuring devices compared with a spectrophotometric reference system. J Dent 2010; 38: e65-e70. DOI: 10.1016/j.jdent.2010.07.006.
  21. Joiner A, Luo W. Tooth colour and whiteness: a review. J Dent 2017; 67S: S3-S10. DOI: 10.1016/j.jdent.2017.09.006.
  22. Shetty S, Gali S, Augustine D, Sv S. Artificial intelligence systems in dental shade-matching: a systematic review. J Prosthodont 2024; 33: 519-532. DOI: 10.1111/jopr.13805.
  23. Goldstein RE, Garber DA. Complete dental bleaching. Chicago: Quintessence Pub. Co.; 1995.
  24. Llena C, Forner L, Vazquez M. Hydrogen peroxide diffusion with and without light activation. Int J Esthet Dent 2016; 11: 430-441.
  25. Petersen M, Braun A, Franzen R. Thermal effects on dental pulp during laser-assisted bleaching procedures with diode lasers in a clinical study. J Clin Med 2024; 13: 2301. DOI: 10.3390/jcm13082301.
  26. Sarkar RG, Bhandary S. Effects of diode laser bleaching and conventional LED bleaching on pulpal temperature using pulp micro­circulation model. J Conserv Dent Endod 2025; 28: 632-636.
  27. Hanna R, Miron IC, Benedicenti S. Feasibility and safety of adopting a new approach in delivering a 450 nm blue laser with a flattop beam profile in vital tooth whitening: a clinical case series with an 8-month follow-up. J Clin Med 2024; 13: 491. DOI: 10.3390/jcm13020491.
  28. El-Sayed EM, Nassar AAG. One year clinical follow-up of the rebound of bleached teeth color using two different in-office bleaching techniques. Egypt Dent J 2024; 70: 2821-2834.
  29. Mailart MC, Sakassegawa PA, Santos KC, Torres CRG, Palo RM, Borges AB. One-year follow-up comparing at-home bleaching systems outcomes and the impact on patient’s satisfaction: randomized clinical trial. J Esthet Restor Dent 2021; 33: 1175-1185.
This is an Open Access journal, all articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Share
without publication fees
without publication fees