Respiratory functional status after conventional and minimally invasive aortic valve replacement surgery – a propensity score analysis

Jarosław Stoliński
,
Robert Musiał
,
Dariusz Plicner
,
Kamil Fijorek
,
Michał Mędrzycki
,
Janusz Andres
,
Bogusław Kapelak

Kardiochirurgia i Torakochirurgia Polska 2017; 14 (1): 5-9
Online publish date: 2017/03/31
View full text Get citation
 
PlumX metrics:
Introduction: Reports describing respiratory function of patients after conventional or minimally invasive cardiac surgery are infrequent.

Aim: To compare pulmonary functional status after conventional (AVR) and after minimally invasive, through right anterior minithoracotomy, aortic valve replacement (RT-AVR).

Material and methods: This was an observational analysis of 212 patients scheduled for RT-AVR and 212 for AVR between January 2011 and December 2014 selected using propensity score matching. Respiratory function based on spirometry examinations is presented.

Results: Hospital mortality was 1.4% in RT-AVR and 1.9% in AVR (p = 0.777). Predicted mortality (EuroSCORE II) was 3.2 ±1.1% in RT-AVR and 3.1 ±1.6% in AVR (p = 0.298). Mechanical ventilation time in intensive care unit (ICU) was 7.3 ±3.9 h for RT-AVR and 9.6 ±5.5 h for AVR patients (p < 0.001). Seven days and 1 month after surgery, the reduction of spirometry functional tests was greater in the AVR group than in the RT-AVR group (p < 0.001). Three months after surgery, all spirometry parameters were still reduced and had not returned to preoperative values in both RT-AVR and AVR groups. However, the difference in spirometry values was no longer statistically significant between RT-AVR and AVR groups. Presence of chronic obstructive pulmonary disease and conventional AVR surgical technique were associated with lower values of spirometry parameters after surgery in linear median regression.

Conclusions: Respiratory function based on spirometry examinations was less impaired after minimally invasive RT-AVR surgery in comparison to conventional AVR surgery through median sternotomy.