eISSN: 1897-4252
ISSN: 1731-5530
Kardiochirurgia i Torakochirurgia Polska/Polish Journal of Thoracic and Cardiovascular Surgery
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2016
vol. 13
 
Share:
Share:
abstract:

The Polish language version of the Confusion Assessment Method – a questionnaire for the screening of consciousness disorders

Krzysztof A. Świerzy
,
Robert Pudlo
,
Bartosz Wesołowski
,
Marcin Garbacz
,
Michał Morawski
,
Izabela Jaworska
,
Mariusz Sołtysik
,
Marian Zembala

Kardiochirurgia i Torakochirurgia Polska 2016; 13 (2): 178-184
Online publish date: 2016/07/03
View full text Get citation
 
PlumX metrics:
Confusion on a somatic basis is a dangerous problem mainly related with aging of the population. Data says that consciousness disorders concern 10-15% of patients in general wards, and up to 50% of patients admitted to geriatric wards. The persistence of the symptoms of confusion results in increase of agitation, disorganization, fear, which increases the risk of self-injuries of patients, it causes the need for parenteral feeding and hydratation, as well as maintaining water balance, and also disturbs cooperation, worsening the course and prognosis of the primary disease. It is believed that consciousness disorders are one of the most difficult diagnostic problems and the most difficult therapy problem among psychotic disorders. So far in Poland there have been no screening evaluation tools to assess the occurrence of confusion on the somatic basis. The purpose of this paper is to introduce the Polish translation of the widely used scale to assess consciousness disorders, intended also for middle personnel of health care – Confusion Assessment Method (CAM). Numerous studies over 16 years established the position of CAM as an exceptionally effective standardized diagnostic test, specifying the sensitivity of 94-100%, specificity from 90-95%, positive predictive value of 91-94%, negative predictive value of 90-100%. The questionnaire and instructions of its interpretation have been translated by doctors with active help from the original creators of CAM. Further studies are required in order to validate and determine the effectiveness of the newly formed diagnostic tool.
keywords:

symptom questionnaire, screening tests, consciousness disorders

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.