eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

4/2020
vol. 12
 
Share:
Share:
abstract:
Original paper

Comparison of post-implant dosimetrics between intraoperatively built custom-linked seeds and loose seeds by sector analysis at 24 hours and 1 month for localized prostate cancer

Eiichiro Okazaki
1
,
Katsuyuki Kuratsukuri
2
,
Tomohiro Nishikawa
3
,
Tomoaki Tanaka
2
,
Mai Sakagami
3
,
Keiko Shibuya
3

1.
Department of Radiation Oncology, Saiseikai Nakatsu Hospital, Osaka, Japan
2.
Department of Urology, Osaka City University Graduate School of Medicine, Osaka, Japan
3.
Department of Diagnostic and Interventional Radiology/Radiation Oncology, Osaka City University Graduate School of Medicine, Osaka, Japan
J Contemp Brachytherapy 2020; 12, 4: 317–326
Online publish date: 2020/08/21
View full text Get citation
 
Purpose
To compare post-implant dosimetrics between intraoperatively built custom-linked (IBCL) seeds and loose seeds (LS) at 24 hours and 1 month by sector analysis, and to evaluate the effect of IBCL seeds with regard to change in dosimetric parameters, in patients with prostate cancer treated with brachytherapy.

Material and methods
Consecutive patients treated for localized prostate cancer who received definitive brachytherapy between March 2013 and October 2017 were retrospectively analyzed. Prostate V100 (PV100), prostate D90 (PD90), prostate V150 (PV150), urethral D30 (UD30), urethral V150 (UV150), and rectal V100 (RV100) were assessed.

Results
Thirty-two patients were treated with LS and 32 patients were treated with IBCL seeds. The median follow-up time was 49.9 months in the LS group and 27.1 months in the IBCL group. PV150, UV150, and UD30 at 24 hours and UD30 at 1 month showed significant difference (F-test), and standard deviation (SD) tended to be lower in the IBCL group. Analysis of change in the variables revealed significance for ΔPV100 and ΔPD90 (F-test, p = 0.014 and < 0.001, respectively), and ΔPV150 and ΔUD30 showed marginal significance (p = 0.084 and 0.097, respectively). PV150, UV150, and UD30 at 24 hours and 1 month were significantly lower in the IBCL group, and there was no significant difference in PV100, PD90, and RV100 compared with the LS group (t-test). The homogeneity index (HI) was significantly higher in the IBCL group (p < 0.001).

Conclusions
In this retrospective single institutional study, there was a decrease in the SD of the dosimetric parameters in the IBCL group, and it was statistically significant in change in the variables between 24 hours and 1 month (F-test). The use of IBCL seeds significantly decreased PV150, UV150, and UD30, and significantly improved HI, without lowering PD90 or PD100.

keywords:

brachytherapy, low-dose-rate, prostate cancer, IBCL seed, loose seed

 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.