twitter
en POLSKI
eISSN: 2719-3209
ISSN: 0023-2157
Klinika Oczna / Acta Ophthalmologica Polonica
Current issue Archive Videos Articles in press About the journal Supplements Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2013
vol. 115
 
Share:
Share:
abstract:
Original paper

Conventional pseudophakic monovision – visual function, patient satisfaction and complications

Wojciech Lubiński
1
,
Monika Cholewa
1
,
Karolina Podborączyńska-Jodko
1

  1. Department of Ophthalmology, Pomeranian Medical University, Szczecin, Poland
Klinika Oczna 2013, 115 (3): 189-193
Online publish date: 2013/09/26
View full text Get citation
 
Introduction
To evaluate visual function, patient satisfaction and complications after cataract surgery with conventional pseudophakic monovision in a 3-month follow-up.

Material and methods
The following parameters were evaluated in a group of 20 selected patients (40 eyes) mean age: 62.15 ± 7.22 years, who underwent bilateral cataract surgery with monofocal lens implantation (Alcon SA60AT) in the conventional monovision procedure 3 months earlier (target refraction: dominant eye-emmetropia, fellow eye – -2.0 D): binocular uncorrected visual acuity for near, intermediate distance and distance (logMAR), contrast sensitivity (CS-CSV-1000), spectacle independence, patient satisfaction (Type Q) and complication rate.

Results
The mean prescription for distance was in -0.01 ± 0.14 D in dominant eyes, and -1.85 ± 0.19 D for near in nondominant eyes. Three months after surgery, patients had a very good binocular distance, near as well as intermediate visual acuities (-0.03 ± 0.09, -0.1 ± 0.11, and -0.39 ± 0.17, respectively). Binocular contrast sensitivity values under mesopic and photopic conditions for distance and under photopic conditions for near fell in the reference range for age. Most patients (80%) did not require any additional correction. Spectacle independence for distance, near and intermediate distances was 100%, 80% and 90%, respectively. General patient satisfaction was very high (9.40/10). There were no postoperative complications.

Conclusions
Cataract surgery with monofocal lens implantation during a conventional monovision procedure (E,-2.0 D) in a selected group of patients offered a very good binocular visual function, a substantial spectacle independence and overall patient satisfaction.

keywords:

pseudophakic monovision, visual function, patient satisfaction, complications

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.