Introduction
Comparison of standard W/W and CFF perimetry in patients with cataract and lens opacities.

Material and methods
Visual field was measured on Octopus 301 perimeter with option „flicker perimetry”. W/W and CFF perimetry (Program G1 in TOP strategy) was performed in 44 eyes with cataract and lens opacities.

Results
Defects in visual field with CFF perimetry were found in 24% of cases but with W/W perimetry in 100% of cases.

Conclusions
Perimetry CFF is a new tool for early detection and follow up of visual field defects in patients with cataract and lens opacities.