eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

2/2019
vol. 11
 
Share:
Share:
abstract:
Original paper

Impact of different dose prescription schedules on EQD2 in high-dose-rate intracavitary brachytherapy of carcinoma cervix

Mohan Kumar
1
,
Revathy Thangaraj
1
,
Ram Charith Alva
1
,
Kirthi Koushik
1
,
Arul Ponni
1
,
Janaki MG Achar
1

1.
Ramaiah Medical College Bengaluru, India
J Contemp Brachytherapy 2019; 11, 2: 189–193
Online publish date: 2019/04/23
View full text Get citation
 
Purpose
To observe the effect of different high-dose-rate (HDR) intracavitary brachytherapy dose schedules on equieffective dose in 2 Gy per fraction (EQD2).

Material and methods
It is a retrospective study involving 50 cervical cancer patients, who received external radiotherapy of 45 Gy in 25 fractions and underwent intracavitary brachytherapy (ICBT). Computed tomography (CT) simulation was done after insertion of the applicators. High-risk clinical target volume (CTVHR) and organs at risk (OARs) such as bladder, rectum, and sigmoid were contoured. Four different plans were generated for each patient, with dose prescriptions of 5.5 Gy × 5 fractions (plan A), 6.5 Gy × 4 fractions (plan B), 7 Gy × 4 fractions (plan C), and 9 Gy × 2 fractions (plan D), delivered to CTVHR. The total EQD2 for 0.1 cm3 and 2 cm3 of bladder, rectum, and sigmoid as well as dose received by 90% of the CTVHR (D90) and point A were calculated. The values were analyzed and compared with available literature.

Results
The mean CTVHR volume was 47.12 ±13.8 cm3. All plans delivered similar EQD2 for 0.1 cm3 and 2 cm3 of sigmoid. Plan D delivered lesser EQD2 compared to other plans for bladder, rectum, D90 CTVHR, and point A (p = 0.0001). Plan C delivered higher EQD2 to OARs compared to other plans (p = 0.001). Plan A, B, and plan C delivered similar EQD2 for D90 CTVHR and point A.

Conclusions
EQD2 of bladder, rectum, sigmoid, D90 CTVHR, and point A were similar with 5.5 Gy × 5 fractions, 6.5 Gy × 4 fractions, and 7 Gy × 4 fractions, whereas EQD2 of 9 Gy × 2 fractions was significantly unfavorable compared to other schedules. Further clinical studies are recommended to observe clinical outcomes.

keywords:

brachytherapy, EQD2, cervical cancer

 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.