Prevalence of a minimal luminal cross sectional area of coronary arteries < 4 mm2 determined by intravascular ultrasound in patients with coronary artery calcium scores of 0-100, 100-200, 200-300, 300-400, and > 400 determined by cardiac computer tomography

John H. Shao
,
Wilbert S. Aronow
,
Gautham Ravipati
,
Kumar Kalapatapu
,
Melvin B. Weiss
,
Albert J. DeLuca
,
Craig E. Monsen
,
Carmen Sorbera
,
Robert N. Belkin
,
Anthony L. Pucillo

Arch Med Sci 2009; 5, 2: 172-174
Online publish date: 2009/07/23
Article file
Get citation
 
 

Introduction
Intravascular ultrasound is considered the reference standard for detection of atherosclerotic plaques [1, 2]. Electron beam computed tomography (CT) is a noninvasive test that helps to visualize coronary atherosclerosis by localization and quantitation of coronary artery calcification (CAC) [3, 4]. The present prospective study compares in 25 patients who had both CT and intravascular ultrasound (IVUS) the accuracy of CAC scores in predicting a minimal luminal cross sectional area of a coronary artery < 4 mm2 [5].
Material and methods
A prospective study was performed in 25 patients (16 men and 9 women), mean age 60 ±8 years, who had IVUS measurements of minimal luminal cross sectional area of coronary artery lesions in patients who had measurements of CAC score for the same coronary artery. The left anterior descending coronary artery was investigated in 18 patients (72%), the left main coronary artery in 3 patients (12%), the right coronary artery in 2 patients (8%), the left circumflex coronary artery in 1 patient (4%), and the first diagonal coronary artery in 1 patient (4%). Intravascular ultrasound was performed as previously described [5]. A MLCSA of coronary arteries < 4 mm2 determined by IVUS was considered the gold standard for significant coronary artery obstruction [5].
The IVUS system used was manufactured in the United States (Boston Scientific Corp., Natick, MA). 40-MHz coronary catheters with 2.5 F at the tip and 3.2 F at the largest dimension, compatible with a 6 F guiding catheter were used. The catheters were advanced over a regular guide wire, usually 0.36 mm (0.014”) in diameter, using a short rail section at the catheter tip, just beyond the 15-cm-long segment within which the spinning transducer can be advanced or withdrawn. The ultrasound catheter tip was slid in over the guidewire and positioned so that the tip was at the farthest away position to be imaged. The sound waves were emitted from the catheter tip, and the catheter also receives and conducts the return echo information out to the external computerized ultrasound equipment which constructs and displays a real time ultrasound image of a thin section of the blood vessel currently surrounding the catheter tip, usually displayed at 30 frames/ second image. The guide wire was kept stationary, and the ultrasound catheter tip was slid backwards, usually under motorized control at a pullback speed of 0.5 mm/s.
Scans for CAC scoring were obtained using a Siemens Somatom Sensation Cardiac computed tomography (CT) system (Siemens AG Medical Solutions, Erlangen, Germany). Calcium scoring was performed as a component of a complete cardiac CT study that included 64 slice coronary CT angiography, or as a stand alone procedure in patients referred for calcium scoring alone. Calcium scans were performed using a spiral scanning protocol (rotation time 0.33 ms, slice collimation 0.6 mm, slice width 3.0 mm, pitch factor 0.2, increment of 1.5 mm, kernel B35) or using a sequential scanning protocol with ECG triggering (rotation time 0.33 ms, slice collimation 0.6 mm, slice width 3.0 mm, kernel B35). Calcium scoring was performed by one of two cardiologists experienced in cardiac CT, employing a TeraRecon Aquarius workstation (TeraRecon, San Mateo, California). A CAC score of 0-100 was considered mild coronary artery disease (CAD), of 100-400 moderate CAD, and of > 400 severe CAD [6].
The cardiologists who made the IVUS measurements were unaware of the CAC scores. The cardiologists who made the CAC score mea-surements were unaware of the IVUS mea-surements.
Student’s t tests were used to analyze continuous variables. Chi-square tests were used to analyze dichotomous variables. An analysis of variance test was performed.
Results
Of the 25 patients, 6 (24%) had a CAC score of 0-100, 13 (52%) had a CAC score of 100-400, and 6 (24%) had a CAC score of > 400. Of the 25 patients, 12 (48%) had a minimal luminal cross sectional area of the coronary arteries investigated by IVUS of < 4 mm2. Percutaneous coronary intervention with stenting was performed in 12 of 12 patients (100%) with a minimal luminal cross sectional area of < 4 mm2 and in none of 13 patients (0%) with a minimal luminal cross sectional area of > 4 mm2.
Table I shows the mean minimal luminal cross sectional area of the coronary arteries visualized by IVUS in patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400. No significant differences were found.
Table II shows the prevalence of a minimal luminal cross sectional area of the coronary arteries visualized by IVUS of < 4 mm2 n patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400. No significant differences were found using the c2 test and the analysis of variance test.
Discussion
A good correlation was observed between calcium quantification by CT and by IVUS [7]. Computed tomography density values measured within plaques by CT in 37 patients who also had IVUS reflect echogenity and plaque composition [8].
However, to the best of our knowledge, no study has been reported showing the mean minimal luminal cross sectional area of the coronary arteries visualized by IVUS in patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400. To the best of our knowledge, no study has also reported the prevalence of a minimal luminal cross sectional area of the coronary arteries visualized by IVUS of < 4 mm2 in patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400.
The present prospective IVUS study showed that the mean mean minimal luminal cross sectional area of the coronary arteries visualized by IVUS was not significantly different in patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400. The present study also showed that the prevalence of a minimal luminal cross sectional area of the coronary arteries visualized by IVUS of < 4 mm2 was not significantly different in patients with CAC scores of 0-100, 100-200, 200-300, 300-400, and > 400. These data indicate that CAC scores determined by CT do not accurately predict significant obstructive CAD diagnosed by IVUS. Therefore, CAC scores cannot be used in clinical practice to predict significant obstructive CAD [9, 10] diagnosed by IVUS.
Acknowledgments
None of the authors have any conflict of interest pertaining to this paper.
References
1. Waller BF, Pinkerton CA, Slack JD. Intravascular ultrasound: a histologic study of vessels during life. The new “gold standard” for vascular imaging. Circulation 1992; 85: 2305-10.
2. Nishioka T, Amanullah AM, Luo H, et al. Clinical validation of intravascular ultrasound imaging for assessment of coronary stenosis severity: comparison with stress myocardial perfusion imaging. J Am Coll Cardiol 1999; 33: 1870-8.
3. Agaston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R. Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 1990; 15: 827-32.
4. Breen J, Sheedy PF 2nd, Schwartz RS, et al. Coronary artery calcification detected with ultrafast CT as an indication of coronary artery disease. Radiology 1992; 185: 435-9.
5. Fujii K, Carlier SG, Mintz GS, et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 2005; 45: 995-8.
6. Kaplan S, Aronow WS, Lai H, et al. Patients with echocardiographic aortic valve calcium or mitral annular calcium have an increased prevalence of moderate or severe coronary artery calcium diagnosed by cardiac computer tomography. Int J Angiol in press.
7. Pundziute G, Schuijf JD, Jukema JW, et al. Head-to-head comparison of coronary plaque evaluation between multislice computed tomography and intravascular ultrasound radiofrequency data analysis. J Am Coll Cardiol Intv 2008; 1: 176-82.
8. Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques. A comparative study with intracoronary ultrasound. J Am Coll Cardiol 2004; 43: 1241-7.
9. Ramdeen N, Aronow WS, Chugh S, Asija A. Patients undergoing coronary angiography because of chest pain with hepatitis C virus seropositivity have a higher prevalence of obstructive coronary artery disease than a control group. Arch Med Sci 2008; 4: 452-4.
10. Rachdev A, Aronow WS, Lai HM, et al. Comparison of left ventricular ejection fraction by single photon computed tomographic myocardial perfusion imaging versus coronary computed tomography angiography. Arch Med Sci 2009; 5: 28-31.
Copyright: © 2009 Termedia & Banach. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.