eISSN: 2299-0046
ISSN: 1642-395X
Advances in Dermatology and Allergology/Postępy Dermatologii i Alergologii
Current issue Archive Manuscripts accepted About the journal Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2022
vol. 39
 
Share:
Share:
Letter to the Editor

The utility of rapid FIA antigen test to detect SARS-CoV-2 infection – preliminary experiences of the Hospital for Infectious Diseases in Warsaw

Andrzej Horban
1
,
Justyna D. Kowalska
1
,
Tomasz Dyda
2
,
Piotr Ząbek
2
,
Hanna Czeszko-Paprocka
3

1.
Department of Adults’ Infectious Diseases, Medical University of Warsaw, Warsaw, Poland
2.
Molecular Diagnostics Laboratory, Hospital for Infectious Diseases, Warsaw, Poland
3.
Central Analytical Laboratory, Hospital for Infectious Diseases, Warsaw, Poland
Adv Dermatol Allergol 2022; XXXIX (3): 613-614
Online publish date: 2020/11/04
Article file
- The utility.pdf  [0.09 MB]
Get citation
 
 

Since the beginning of the SARS-CoV-2 epidemic, several diagnostic techniques have been developed to detect the infection. Real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay is considered the gold standard in confirming the diagnosis of COVID-19 in clinical settings [1]. However RT-PCR technology is considered time consuming, costly and requires significant resources, both in terms of available laboratory equipment and experienced staff. Therefore, using RT-PCR in epidemiological surveillance or in mass testing is difficult and meeting the necessary number of tests to be performed has been shown to be impossible in practical terms. On the contrary, antigen tests can be used as point-of-care diagnostics with a rapid turnaround time and could play a critical role in implementation of infection prevention and control strategies. The Centres of Disease Control and Prevention (CDC) provides interim guidance to support effective use of antigen tests for different testing situations as they become available on the market and are therefore bought by physicians [2]. The World Health Organisation (WHO) does not provide a specific recommendation on the basis of which, before these tests can be recommended, they must be further validated in given populations and settings [35]. In fact there is a lack of reliable research regarding the usefulness of these tests in the laboratory diagnosis of infections caused by SARS-CoV-2 [6]. Therefore, we performed comparative testing for the antigen test available from the Ministry of Health resources to all public health services using RT-PCR test as the gold standard.

PCL COVID-19 Ag Rapid FIA (Ag Rapid FIA) is an in vitro diagnostic medical device using sandwich fluorescent immunoassay to qualitatively detect SARS-CoV-2 antigen in human nasopharyngeal and sputum specimens [7]. We have performed analyses of 266 nasopharyngeal samples collected from patients hospitalized in the Hospital for Infectious Diseases in Warsaw. SARS-Cov-2 infection was confirmed in 40 samples by real time RT-PCR (SARS-CoV-2 Genesig Real-Time PCR Assay, Vitassay). Sixteen of these samples were positive in PCL COVID-19 (Ag Rapid FIA) test (Serial no. COV05-2003N405 and COV05-2003N401) and five of 226 SARS-CoV-2 negative samples were positive in Ag Rapid FIA. Basing on these results, sensitivity was calculated as 40% (16 of 40) and specificity as 98% (221 of 226).

In addition, we recalculated sensitivity of Ag Rapid FIA for different RT-PCR cycle threshold (CT) ranges. The CT is defined as the number of cycles required for the fluorescent signal used in the RT-PCR assay to cross the background threshold and is inversely proportional to the amount of target nucleic acid in the sample [8]. Briefly, CT < 29 is strong positive reactions indicative of a large amount of nucleic acid in the sample, CT of 30–37 indicates moderate amounts of target nucleic acid and CT of 38–40 indicates a weak reaction and minimal amounts of nucleic acid.

All positive results obtained in Ag Rapid FIA were for samples with CT of 17-28 and false negative Ag Rapid FIA in CT of 26-39. We observed that sensitivity of Ag Rapid FIA depended on the CT value of RT PCR for SARS-CoV-2 positive samples (Table 1).

Table 1

Ag Rapid FIA test results stratified by the cycle threshold (CT) value in SARS-CoV-2 RT-PCR

CT value in RT-PCR testN Positive Ag Rapid FIANegative Ag Rapid FIASensitivity of Ag Rapid FIA (%)
≤ 222016480
23–3262323052
33–4079215827
≤ 40161699242
≤ 3282483458

It has been noted by laboratory technicians that using two drops of assay buffer was not always sufficient to complete the test with the result stated as “no sample or insufficient sample volume”. In the subset of tests, the results were read according to the instructions after 10 min and after a further 10 min, extending the incubation. It did not change the negative results.

In concordance with other studies, we found that point-of-care antigen tests have a lower sensitivity and similar specificity for detecting SARS-CoV-2 compared to RT-PCR tests. A recent literature review found that antigen test sensitivity varied from 0% to 94% across published studies with the average sensitivity of 56.2% (95% CI: 29.5–79.8%) and average specificity of 99.5% (95% CI: 98.1–99.9%) [9]. In our study the overall sensitivity for the tested Ag Rapid FIA test was 40%, thus not acceptable for its routine use for laboratory diagnosis of the SARS-CoV-2 infection. At the same time our results suggest that this test could be utilized in the group of patients with the highest titre of the SARS-CoV-2 virus in the upper respiratory tract, therefore with the higher infectivity [10]. Taking into account its current availability and short time to receive the result it is possible to use this test for immediate identification and isolation of the most infectious patients in specific settings e.g. at emergency departments, schools or nursing home facilities. We advise to interpret a positive Ag Rapid FIA as a potential SARS-CoV-2 infection requiring further confirmation with RT-PCR. On the contrary, a negative Ag Rapid FIA should be interpreted as inconclusive.

Conflict of interest

The authors declare no conflict of interest.

References

1 

Corman VM, Landt O, Kaiser M, et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR. Euro Surveill 2020, 25: 2000045.

2 

Centres for Disease Control and Prevention (CDC) 2020. Interim Guidance for Rapid Antigen Testing for SARS-CoV-2. Available at: https://www.cdc.gov/coronavirus/2019-ncov/lab/resources/antigen-tests-guidelines.html. Accssed on: 12.09.2020.

3 

World Health Organization (2020). Laboratory testing for coronavirus disease 2019 (COVID-19) in suspected human cases: interim guidance, 19 March 2020. World Health Organization. Available at: https://www.who.int/publications-detail/laboratorytesting-for-2019-novel-coronavirus-in-suspectedhuman-cases-20200117. Accessed on: 12.09.2020.

4 

ECDC Case definition and European surveillance for COVID-19, as of 2 March 2020. Available at: https://www.ecdc.europa.eu/en/case-definition-and-europeansurveillance-human-infection-novel-coronavirus-2019-ncov. Accessed on: 12.09.2020.

5 

WHO. Advice on the use of point-of-care immunodiagnostic tests for COVID-19. Available at: https://www.who.int/news-room/commentaries/detail/advice-on-the-use-of-point-of-care-immunodiagnostic-tests-for-covid-19. Accessed on: 12.09.2020.

6 

Rastawicki W, Rokosz-Chudziak N. Characteristics and assessment of the usefulness of serological tests in the diagnostic of infections caused by coronavirus SARS-CoV-2 on the basis of available manufacturer’s data and literature review. Przegl Epidemiol 2020; 74: 49-68.

7 

PCL COVID19 Ag Rapid FIA (Antigen Test Kit) Product detailes. Available at: https://www.buykorea.org/bk/byr/product/GOODS_DETAIL-3253041.do. Accessed on: 12.09.2020.

8 

Buchan BW, Hoff JS, Gmehlin CG, et al. Distribution of SARS-CoV-2 PCR cycle threshold values provide practical insight into overall and target-specific sensitivity among symptomatic patients. Am J Clin Pathol 2020; 154: 479-85.

9 

Dinnes J, Deeks JJ, Adriano A, et al. Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev 2020; 8: CD013705.

10 

To KK, Tsang OT, Leung WS, et al. Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study. Lancet Infect Dis 2020; 20: 565-74.

Copyright: © 2020 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.