eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

1/2024
vol. 16
 
Share:
Share:
abstract:
Original paper

Dosimetric comparison of intra-cavitary brachytherapy technique with free-hand (intra-cavitary + interstitial) technique in cervical cancer

Sumukh Jamadagni
1
,
Arul Ponni
2
,
Revathy P
2

1.
Department of Radiation Oncology, Vijayanagar Institute of Medical Sciences, Bellary, India
2.
2Department of Radiation Oncology, Ramaiah Medical College and Hospitals, Ramaiah University of Applied Sciences, Bengaluru, India
J Contemp Brachytherapy 2024; 16, 1: 28–34
Online publish date: 2024/02/23
View full text Get citation
 
Purpose:
The aim of the study was to dosimetrically compare intra-cavitary brachytherapy technique (ICBT) with free-hand (intra-cavitary + interstitial, IC + IS) technique.

Material and methods:
Twenty seven locally advanced carcinoma cervix patients were included in the study. Patients with more than medial 1/3rd parametrial residual disease without extending upto lateral pelvic wall were included, following external beam radiotherapy (EBRT), in which cobalt-60 high-dose-rate (60Co HDR) brachytherapy source was used. Dose for both plans were 6.5 Gy × 4 fractions, 2 fractions per day, 6 hours apart, over 2 days. Free-hand brachytherapy technique, consisted of placement of central tandem and 2 ovoids along with needles without using template, was applied. Two plans were generated by activating and deactivating the needles, and compared by normalizing to V100.

Results:
A total of 79 needles were applied. Using paired-t test, dosimetric comparison of both the plans was done. Free-hand plan had a significant higher mean V90 (volume receiving 90% of the dose) of 94.2% compared with 87.22% in ICBT plan (p ≤ 0.0001). Free-hand and ICBT plans presented a mean V100 values of 89.06% and 81.51% (p ≤ 0.0001), respectively, favoring free-hand plan. The mean D90 (dose to 90% volume), D98, and D100 of free-hand plan were 6.28 Gray (Gy), 4.91 Gy, and 3.62 Gy, respectively, but equivalent parameters in ICBT plan were 5.26 Gy, 3.72 Gy, and 2.61 Gy, with p value ≤ 0.0001. In both the plans, D2cc of the bladder, rectum, and sigmoid were 4.59 Gy, 3.98 Gy, 2.77 Gy, and 4.46 Gy, 3.90 Gy, 2.67 Gy, respectively, with no statistical significance.

Conclusions:
Free-hand brachytherapy (IC + IS) achieves a statistically significant better dose distribution to high-risk clinical target volume (HR-CTV) comparing with ICBT technique with similar dose to organs at risk.

keywords:

carcinoma cervix, intra-cavitary brachytherapy, IC + IS, free-hand technique, dose volume histogram, organs at risk

 
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.