eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2020
vol. 16
 
Share:
Share:
abstract:
Letter to the Editor

Bridge to avoid ICD implantation with wearable cardioverter defibrillators

Franco Zoppo
1
,
Giacomo Mugnai
2
,
Antonio Lupo
3
,
Francesca Zerbo
3

1.
Ospedale Civile, Gorizia, Italy
2.
Ospedale Civile, Arzignano, Italy
3.
Ospedale Civile, Mirano, Italy
Adv Interv Cardiol 2020; 16, 2 (60): 227–228
Online publish date: 2020/06/23
View full text Get citation
 
The wearable cardioverter-defibrillator (WCD) is an option [1, 2] for patients at high risk, not yet candidates for an implantable cardioverter-defibrillator (ICD) [3, 4]. A cost/effectiveness analysis should take into account fixed (device-related) and running (hospitalization, ICD-related risk of infections) costs.
We present a retrospective analysis with regard to the raw costs of all consecutive WCDs (LifeVest; Zoll Medical) applied from April 2017 to September 2018 in our center.
Clinical and demographic data were collected in our hospital database.
From the study period, the only commercial policy of our WCD Country Zoll Medical Distributor was to offer the device for a monthly rent with an average cost of € 3,500 (3,400 to 4,000).
Statistical analysis was performed by means of SPSS 20.0 (IBM Inc., Armonk, New York, USA).
Written informed consent was obtained from all the patients to accept and be followed up with the WCD. Since the study relates to an economic analysis of care strategies and does not include any assessment of patient clinical status, therapies and care, it was notified to our Institutional Ethics Committee according with their rules.
A total of 16 patients (57.7 ±14.8 years old; 75% males) were enrolled in the study (4 patients with acute myocarditis, 4 patients with a recent myocardial infarction, 4 patients with a recent dilated cardiomyopathy diagnosis, 2 oncologic patients receiving cardiotoxic chemotherapy and 2 patients with nonsustained ventricular arrhythmias considered at high risk).
No patients presented sustained ventricular arrhythmias during the observation period; neither appropriate nor inappropriate shocks were delivered by the device.
At the end of the “wearing period”, at re-assessment, 11/16 patients (69%), did not have indications for ICD implantation (NO-ICD study group), who were compared with the 5/16 (31%) patients who underwent ICD implantation (ICD study group).
In the univariate comparison no variable characterized the study groups (Table I).
In the NO-ICD study patients, the mean left ventricular ejection fraction (LVEF) values at baseline and at the end of WCD wearing period were 32.2 ±10.1 vs. 44.7 ±7.4% respectively.
The WCD rental cost for the NO-ICD group (average 26 months for all patients’ cumulative rental period) was € 91,000 versus € 70,000 for the ICD group (average 20 months for all...


View full text...
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.