eISSN: 1897-4252
ISSN: 1731-5530
Kardiochirurgia i Torakochirurgia Polska/Polish Journal of Thoracic and Cardiovascular Surgery
Current issue Archive Manuscripts accepted About the journal Supplements Editorial board Reviewers Abstracting and indexing Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
4/2012
vol. 9
 
Share:
Share:

Fatal outcome of early postoperative myocardial infarction after implantation of aortic valve bioprosthesis and left internal thoracic artery anastomosis to left anterior descending coronary artery caused by closure of unchanged circumflex coronary artery

Karol Bartczak
,
Piotr Kula
,
Radosław Zwoliński
,
Arkadiusz Ammer
,
Anna Kośmider
,
Andrzej Walczak
,
Andrzej Banyś
,
Ryszard Jaszewski

Kardiochirurgia i Torakochirurgia Polska 2012; 9 (4): 424–427
Online publish date: 2013/01/14
Article file
- 04 Bartczak.pdf  [0.79 MB]
Get citation
 
PlumX metrics:
 

Case report

The authors present a case of a 67-year-old man operated on for critical aortic stenosis (peak aortic gradient 108 mm Hg, mean 67 mm Hg, aortic valve area 0.8 cm2), severe calcific degeneration as well as fibrosis of the leaflets and the annulus involving the mitral valve, with ejection fraction of 47%. Coronary angiography revealed an isolated long proximal 95% narrowing in the left descending artery; all other coronary arteries were without any lesions (Fig. 1). ECG showed a 1st degree AV block (PR 230-250 ms). The fibrinogen level was 7.5 g/l and the thrombin time was 24 s. An Aortic Medtronic Hancock 23 A supra annular bioprosthesis had been implanted with concomitant cardiac artery bypass of the left internal thoracic artery to the left descending artery in extracorporeal circulation. Intraoperative examination revealed massive calcific degeneration within the three leaflets of the functionally bileaflet aortic valve and the annulus, reaching the intraventricular septum and the anterior leaflet of the mitral valve. The aortic cross-clamping time was 101 minutes and the extracorporeal circulation time was 130 minutes. Cold crystalloid antegrade cardioplegic solution was used for cardiac protection, administered directly to the ostia of the left and right coronary arteries (dosage: 20 ml/kg of body weight every 20 minutes). After declamping the aorta and restarting the heart, we observed a 3rd degree AV block. An epicardial cardiostimulator was introduced. After 23 minutes of reperfusion with effective heart stimulation, the extracorporeal circulation was stopped. There was no need for the use of catecholamines. The patient was then transferred to a postoperative room in stable condition. After 3 hours, the patient’s condition destabilized. We noted a progressive decrease in arterial blood pressure, at which point we introduced an infusion of catecholamines in increasing doses and used an intra-aortic balloon pump (IABP) – with little response. ECG reveled ischemia of the lateral and posterior walls of the heart. Transesophageal echocardiography showed hypo/akinesia of the lateral and posterior walls of the heart, weakening of the global contraction function with ejection fraction of 36% and proper functioning of the prosthesis with no signs of perivalvular leak. Due to the lack of a positive response to the provided treatment, in the 5th postoperative hour, the patient was referred for immediate coronary angiography, which revealed the amputation of the initially unchanged circumflex artery and an additional 90% narrowing of the medial segment of the left descending artery. The left thoracic artery was narrowed, but flow was preserved (Fig. 2). Percutaneous cardiac intervention was performed with the implantation of 2 bare-metal stents in the proximal and medial segments of the left descending artery with TIMI 3 grade flow and balloon angioplasty of the circumflex artery with TIMI 3 grade flow (Fig. 3). Despite the successful percutaneous cardiac intervention on the amputated and narrowed coronary arteries and the initial improvement, the patient’s condition declined during the first postoperative day. The patient exhibited a gradual decrease in artery blood pressure, anuria (continuous veno-venous hemodiafiltration was performed), elevation of myocardial infarction markers (elevation of high-sensitivity troponin T from 2840 to 10 000 ng/ml) and multi-organ failure. On the second postoperative day, death was pronounced due to the lack of response of the heart to cardiostimulation and the continuous decrease of artery blood pressure (to an indeterminable level) despite resuscitation.

Discussion

Perioperative myocardial infarction after aortic valve replacement caused by embolus is a very rare, but serious and potentially lethal complication. Symptoms of myocardial ischemia, such as low cardiac output syndrome, depend on which cardiac vessel is obstructed. According to the literature, occlusion of the left main trunk is one of the most serious and dangerous complications after aortic or mitral valve replacement [1, 2] and it occurs in 1 to 5% of patients without any changes in the coronary arteries prior to surgery [1].

In many cases, early acute myocardial ischemia may be caused by technical mistakes during the implantation of artificial valves. Implanting an oversized artificial valve whose edges could occlude the coronary ostia and disable proper coronary artery perfusion may serve as an example [3]. Microinjuries, local immunological and hyperplastic reactions related to the infusion pressure of cardioplegia, and the low temperature of the cardioplegic solution administered directly to the ostia of the coronary arteries constitute other possible explanations for myocardial ischemia after AVR. However, myocardial ischemia in such cases occurs later in the postoperative period [4, 5].

In patients with acute myocardial ischemia after AVR, it is important to take into consideration the ostial or proximal narrowing or occlusion of the coronary artery due to coronary artery spasm or calcium embolism related to aortic valve decalcification, thrombus, bacterial embolism or air [6, 7]. In these cases, coronary artery occlusion may cause difficulties in restoring circulation after extracorporeal circulation or recurrent ventricular fibrillation.

We described a case of a patient who, in the 3rd postoperative hour, developed myocardial ischemia which then continued to progress. Analyzing the possible causes, we have to take into consideration the calcific embolism released during normal heart activity or thrombus. Preoperative coronary angiography revealed a proximal narrowing in the left descending artery just before the orifice of the circumflex artery (Fig. 2), which may explain the circumflex artery occlusion.

In the majority of publications, the authors indicate the necessity of immediate coronary angiography in cases of decreased artery blood pressure, ventricular arrhythmias, and progressing acute heart insufficiency during the early postoperative period after aortic valve replacement [6-8]. It is not advisable to wait for the elevation of cardiac ischemia markers.

The control coronary angiography performed in the 5th postoperative hour enabled us to confirm our previous presumptions concerning the circumflex coronary artery occlusion, successfully restore the flow in this vessel, and perform a percutaneous intervention in the primary narrowed left descending artery. It seems that our reaction was correct and the achieved TIMI 3 grade flow in the occluded artery significantly improved our prognosis. Unfortunately, it did not save the patient. Presumably, irreversible lesions in the microcirculation had already developed.

Balloon coronary angioplasty and stent implantation are the quickest methods of restoring the flow in the occluded coronary artery either in the left main or proximal segment [9, 10]. However, it should be emphasized that this method is not successful in every case. Sometimes surgical revascularization of the heart is the only option, despite the much higher risk. Leontiew et al. presented a case of postoperative myocardial infarction caused by closure of the left main coronary artery in a 62-year-old patient after aortic bioprosthesis implantation. The patient underwent off-pump coronary artery bypass grafting with the implantation of two saphenous grafts to the left descending artery and the circumflex artery. Postoperatively, extracorporeal membrane oxygenation support had to be employed for 10 days and was extremely complicated. Despite that, the patient was discharged from the hospital after three months [8].

Conclusions

Acute myocardial ischemia caused by coronary occlusion resulting from calcium debris or thrombus, taking place early after aortic valve replacement, is not a common complication. Despite prompt intervention, it may be fatal in many cases.



This paper was presented at the Torakoneptunalia 2011 Conference, Jurata 23-24 of September 2011.

Literature

1. Funada A, Mizuno S, Ohsato K, Murakami T, Moriuchi I, Misawa K, Kokado H, Shimada Y, Ishida K, Ohashi H. Three cases of iatrogenic coronary ostial stenosis after aortic valve replacement. Circ J 2006; 70: 1312-1317.

2. Calafiore AM, Iacò AL, Varone E, Bosco P, Di Mauro M. Distortion of the proximal circumflex artery during mitral valve repair. J Card Surg 2010; 25: 163-165.

3. Turillazzi E, Di Giammarco G, Neri M, Bello S, Riezzo I, Fineschi V. Coronary ostia obstruction after replacement of aortic valve prosthesis. Diagn Pathol 2011; 6: 72.

4. Gruber S, Ng CK, Schwarz C, Auer J. Unstable angina early after aortic valve replacement surgery in a female patient with normal coronary arteries preoperatively – a case report. J Cardiothorac Surg 2009; 4: 29.

5. Goździk A, Pelczar M, Skalik R, Obremska M, Goździk W, Kustrzycki W. Zawał okołooperacyjny u pacjentki bez zmian w naczyniach wieńcowych poddanej planowej operacji wymiany zastawki aortalnej. Kardiochirur Torakochirur Pol 2007; 4: 199-203.

6. Umran S, Chetty G, Sarkar PK. Acute right coronary ostial stenosis during aortic valve replacement. Int J Prev Med 2012; 3: 295-297.

7. Levis JT, Schultz G, Lee PC. Acute myocardial infarction due to coronary artery embolism in a patient with a tissue aortic valve replacement. Perm J 2011; 15: 82-86.

8. Leontyev S, Borger MA, Battellini R, Seeburger J, Lehmann S, Légaré JF, Mohr FW. Embolic occlusion of the left main coronary artery following an isolated aortic valve replacement. J Card Surg 2011; 26: 168-170.

9. Ziakas AG, Economou FI, Charokopos NA, Pitsis AA, Parharidou DG, Papadopoulos TI, Parharidis GE. Coronary ostial stenosis after aortic valve replacement: successful treatment of 2 patients with drug-eluting stents. Tex Heart Inst J 2010; 37: 465-468.

10. Raja Y, Routledge HC, Doshi SN. Coronary stenting for iatrogenic stenosis of the left main coronary artery post-aortic valve replacement: an alternative treatment? Eur J Cardiothorac Surg 2011; 39: 398-400.
Copyright: © 2013 Polish Society of Cardiothoracic Surgeons (Polskie Towarzystwo KardioTorakochirurgów) and the editors of the Polish Journal of Cardio-Thoracic Surgery (Kardiochirurgia i Torakochirurgia Polska). This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.