Original paper Transcatheter implantation of the biological Sapien Edwards valve in the pulmonary position – first experiences
Marcin Demkow, Witold Rużyłło, Elżbieta Katarzyna Biernacka, Mirosław Kowalski, Mateusz Śpiewak, Göran Olivecrona, Piotr Hoffman
Post Kardiol Interw 2011; 7, 2 (24): 111–115
We present the first in Poland, and among the first in Europe, cases of transcatheter implantation of the biological Sapien Edwards valve in the pulmonary position. The valves were implanted successfully without periprocedural complications in 2 patients with postoperative right ventricular outflow tract dysfunction.