eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
3/2019
vol. 15
 
Share:
Share:
abstract:
Review paper

Percutaneous access to coronary arteries in patients after transcatheter aortic valve implantation procedures – is it a real problem?

Piotr Chodór
1
,
Krzysztof Wilczek
2
,
Roman Przybylski
3
,
Jerzy Nożyński
4
,
Łukasz Włoch
1
,
Zbigniew Kalarus
1

1.
Department of Cardiology, Congenital Heart Diseases and Electrotherapy, Medical University of Silesia, Silesian Center for Heart Diseases, Zabrze, Poland
2.
3rd Department of Cardiology, Medical University of Silesia, Silesian Center for Heart Diseases, Zabrze, Poland
3.
Department of Cardiac Surgery and Transplantology, Medical University of Silesia, Silesian Center for Heart Diseases, Zabrze, Poland
4.
Department of Histopathology, Silesian Center for Heart Diseases, Zabrze, Poland
Adv Interv Cardiol 2019; 15, 3 (57): 274–282
Online publish date: 2019/09/18
View full text Get citation
 
Transcatheter aortic valve implantation (TAVI) is still developing and changing our approach to treating patients with severe symptomatic aortic stenosis. Aortic stenosis frequently coexists with coronary artery disease. Both diseases have similar risk factors for their development and one should expect a future progression of coronary artery disease. The current guidelines have expanded TAVI indications to include intermediate-risk patients, and perhaps they will be expanded to include low-risk patients in the future. Survival after TAVI in younger patients will depend on the durability of the aortic valves and methods of coronary artery disease treatment. This paper presents some aspects of performing coronary angiography and percutaneous coronary intervention in patients who had TAVI performed using the two most popular aortic valves – balloon expandable aortic valves (Edward Sapien/Edward Sapien XT/Sapien 3) and self-expandable aortic valves (CoreValve/Evolut R) – on the basis of several examples. This paper also focuses on technical aspects associated with a proper implantation of aortic valves to ensure easy access to coronary arteries, as well as on possible problems when the implantation is not optimal. We discuss interactions between the structure of the aortic valve stent, catheters, commissures of new aortic valves, and coronary ostia.
keywords:

transcatheter aortic valve implantation, coronary percutaneous intervention, coronary artery disease

Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.