eISSN: 1897-4295
ISSN: 1734-9338
Advances in Interventional Cardiology/Postępy w Kardiologii Interwencyjnej
Current issue Archive Manuscripts accepted About the journal Editorial board Abstracting and indexing Subscription Contact Instructions for authors Publication charge Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
2/2018
vol. 14
 
Share:
Share:
Image in intervention

Staged percutaneous angioplasty of a long calcified left anterior descending artery with rotablation in a patient with stable angina

Jakub Podolec
,
Piotr Szolc
,
Monika Durak
,
Wojciech Zajdel
,
Łukasz Niewiara
,
Krzysztof Żmudka

Adv Interv Cardiol 2018; 14, 2 (52): 206–207
Online publish date: 2018/06/19
Article file
- staged.pdf  [0.11 MB]
Get citation
 
 
A 68-year-old female patient was admitted to the Department of Interventional Cardiology for the next stage of percutaneous coronary intervention (PCI) of a long, heavy calcified lesion in the left anterior descending (LAD) artery. The patient was treated for arterial hypertension, dyslipidemia and diabetes mellitus type 2. One month prior to admission, the patient underwent PCI of the circumflex artery. The patient still reported symptoms of stable angina (class II according the CCS classification).
The procedure was performed using right radial artery access. Distal parts of the LAD and diagonal branch (Dg2) were secured using Sion Blue guidewires. All of the compliant and non-compliant (NC) balloons starting from 2.0/20 mm, NC Emerge 2.5/15 mm and NC Emerge 3.0/15 mm with pressures up to 26 atm were used for pre-dilatation and crushed during the inflation. A strongly calcified, critical narrowing in the LAD was still present. The first attempt at delivering the Flextome Cutting Balloon 2.5/15 mm using the buddy-wire technique was unsuccessful. Introduction of the GuideLiner catheter facilitated inflation of the Flextome Cutting Balloon 2.5/15 mm. Due to the persistent, calcified narrowing with no improvement, the operator decided to perform the rotablation procedure. The RotaWire was introduced to the distal part of the LAD and 4 passages of Burr 1.5 160000 rpm (8 s in duration each) were performed. The next inflations of the Flextome Cutting Balloon with pressures of 6–12 atm and NC Emerge 3.0/8 mm with pressures of 18–24 atm were made. The effect was suboptimal with residual stenosis of 70%. Due to the large dose of contrast infusion, prolonged radiation time, and clinically and angiographically stable condition of the patient, the procedure was terminated.
Five days later, the next attempt via right femoral access with a 7 Fr catheter was performed. The distal part of the LAD was secured using Extra Support Rota-Wire. Three passages with Burr 1.75 mm 160000 rpm and another 3 passages of Burr 2.0 mm 160000 rpm (8 s in duration) were needed. Inflation of the NC balloon 3.0/15 mm with a pressure up to 20 atm was made, finally achieving successful pre-dilatation of the LAD. Angiography revealed linear dissection in the mid LAD. The first attempt at stent delivery was unsuccessful but the use of the GuideLiner catheter facilitated implantation of the Orsiro 3.0/40 mm stent in the mid LAD (10 atm). The dissection was fully covered. Next, the Xience 3.5/18 mm stent was implanted in the proximal LAD with a pressure of 10 atm. Post-dilatation over the whole length of the stent was done using a 3.5/18 mm balloon with pressure up to 18 atm. The final result of the angioplasty was optimal with TIMI 3 flow and no residual stenosis (Figure 1). Two days later, the patient was discharged from the hospital.
Percutaneous treatment of long, highly calcified lesions in the coronary arteries can be challenging. It is crucial to optimally prepare the lesion prior to stent implantation. The Rotablation technique, as well as use of the GuideLiner catheter, is often necessary to achieve an optimal result [1–3]. Prolonged contrast injection and radiation exposure time should be monitored and the procedure should be staged, if necessary, to decrease the risk of contrast-induced nephropathy. The incidence of complications during rotablation has dropped over the last 3 years and the method should be more often considered in treatment of calcified lesions [4]. Careful rotablation with a larger burr is of great advantage to create a sufficient lumen size before stent implantation.

Conflict of interest

The authors declare no conflict of interest.

References

1. Hachinohe D, Kashima Y, Kanno D, et al. Rotational atherectomy and new-generation drug-eluting stent implantation. Catheter Cardiovasc Interv 2018; 91: 1026-34.
2. Cuenza LR, Jayme AC, Khe Sui JH. Clinical outcomes of patients undergoing rotational atherectomy followed by drug-eluting stent implantation: a single-center real-world experience. Heart Views 2017; 18: 115-20.
3. Jinnouchi H, Kuramitsu S, Shinozaki T, et al. Five-year clinical outcomes after drug-eluting stent implantation following rotational atherectomy for heavily calcified lesions. Circ J 2018; 82: 983-91.
4. Januszek R, Siudak Z, Dziewierz A, et al. Predictors of in-hospital effectiveness and complications of rotational atherectomy (from the ORPKI Polish National Registry 2014-2016). Catheter Cardiovasc Interv 2017. doi:10.1002/ccd.27372.
Copyright: © 2018 Termedia Sp. z o. o. This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License (http://creativecommons.org/licenses/by-nc-sa/4.0/), allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
Quick links
© 2024 Termedia Sp. z o.o.
Developed by Bentus.