Journal of Contemporary Brachytherapy
eISSN: 2081-2841
ISSN: 1689-832X
Journal of Contemporary Brachytherapy
Current Issue Archive Supplements Articles in Press Journal Information Aims and Scope Editorial Office Editorial Board Register as Author Register as Reviewer Instructions for Authors Abstracting and indexing Subscription Advertising Information Links
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank

1/2025
vol. 17
 
Share:
Share:
abstract:
Original paper

Active ultrasound tracking method for prostate brachytherapy using acoustic needle prototype and sonomicrometry

Marek Belohlavek
1
,
Minako Katayama
1
,
Christopher L. Deufel
2

  1. Department of Cardiovascular Medicine, Mayo Clinic College of Medicine and Science, Scottsdale, AZ, USA
  2. Department of Radiation Oncology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
J Contemp Brachytherapy 2025; 17, 1: 54–61
Online publish date: 2025/02/27
View full text Get citation
 
Purpose:
This study examined whether sonomicrometry can measure displacements of active ultrasound-tracked needle prototype for prostate brachytherapy application with high linearity, accuracy, and precision as well as triangulate the needle’s motion relative to intra-rectal ultrasound probe.

Material and methods:
Sonomicrometry detects time-of-flight (ToF) of ultrasound signal transmitted from an active ultrasound-tracked needle (customized with a piezo-electric tracking sensor) to independent sensor. The transmission was tested in water for displacements parallel and perpendicular to the needle axis using distances of up to 35 mm. Three-dimensional (3D) tracking of the active ultrasound-tracked needle utilized a simulated intra-rectal ultrasound probe fitted with 5 piezo-electric sensors, and a sonomicrometry triangulation algorithm was used to measure the distances of the needle from the probe.

Results:
Incremental displacements of the active ultrasound-tracked needle were measured by sonomicrometry with strong linearity (R ≥ 0.999), high accuracy (mean difference ≤ 0.55 mm), and precision (1.96 × standard deviation of the mean difference ≤ 0.22 mm) compared with a reference. Sporadic false triggering of ToF detection was eliminated by signal inversion. Acoustic spatial tracking by the off-line triangulation algorithm produced virtual 3D wire meshes, which closely spatially overlapped with the corresponding (ground-truth) video clips of active ultrasound-tracked needle movement at several testing time points.

Conclusions:
We introduced an experimental active ultrasound-tracked needle and employed sonomicrometry to measure the needle’s displacements and triangulate its spatial position. The measurements and 3D spatial tracking yielded promising results for potential prostate brachytherapy applications. Clinical implementation will necessitate developments of automated triggering, real-time tracking, and a commercially viable acoustic needle design.

keywords:

prostate brachytherapy, brachytherapy tracking, sonomicrometry, active tracking needle

 
Quick links
© 2025 Termedia Sp. z o.o.
Developed by Bentus.